Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsSIC | 2771 | Greeting Cards |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0117 # 01 Y:2013 | 01 | 2013 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $8,640 | $0 | Implemented |
TT0117 # 02 Y:2013 | 02 | 2013 | DISCONNECT BALLASTS | $517 | $0 | Not Implemented |
CO0480 # 03 Y:2001 | 03 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,810 | $1,470 | Implemented |
CO0480 # 01 Y:2001 | 01 | 2001 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,830 | $8,000 | Not Implemented |
CO0480 # 02 Y:2001 | 02 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,250 | $12,950 | Not Implemented |
CO0480 # 04 Y:2001 | 04 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,810 | $3,750 | Implemented |
CO0480 # 05 Y:2001 | 05 | 2001 | USE OPTIMUM TEMPERATURE | $610 | $200 | Not Implemented |
CO0480 # 06 Y:2001 | 06 | 2001 | USE OPTIMUM TEMPERATURE | $500 | $0 | Not Implemented |
CO0480 # 07 Y:2001 | 07 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $460 | $60 | Not Implemented |
CO0480 # 08 Y:2001 | 08 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $30 | $0 | Implemented |
WI0276 # 02 Y:1996 | 02 | 1996 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $3,400 | $0 | Implemented |
WI0276 # 10 Y:1996 | 10 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $140 | $0 | Not Implemented |
WI0276 # 09 Y:1996 | 09 | 1996 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $404 | $0 | Not Implemented |
WI0276 # 08 Y:1996 | 08 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $440 | $500 | Implemented |
WI0276 # 07 Y:1996 | 07 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $318 | $1,380 | Not Implemented |
WI0276 # 06 Y:1996 | 06 | 1996 | INSULATE BARE EQUIPMENT | $1,122 | $2,310 | Not Implemented |
WI0276 # 05 Y:1996 | 05 | 1996 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $2,230 | $0 | Not Implemented |
WI0276 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,022 | $2,144 | Not Implemented |
WI0276 # 03 Y:1996 | 03 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,454 | $0 | Not Implemented |
WI0276 # 01 Y:1996 | 01 | 1996 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $4,740 | $15,000 | Not Implemented |
TN0571 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $518 | $600 | Not Implemented |
TN0571 # 05 Y:1996 | 05 | 1996 | CONVERT TO AQUEOUS CLEANING SYSTEM | $687 | $1,600 | Implemented |
TN0571 # 04 Y:1996 | 04 | 1996 | USE SYNTHETIC LUBRICANT | $748 | $0 | Implemented |
TN0571 # 03 Y:1996 | 03 | 1996 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $1,358 | $0 | Not Implemented |
TN0571 # 02 Y:1996 | 02 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,933 | $2,100 | Not Implemented |