Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
131
matching recommendationsSIC | 2782 | Blankbooks And Looseleaf Binders |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0083 # 02 Y:1990 | 02 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,462 | $2,500 | Not Implemented |
WI0083 # 03 Y:1990 | 03 | 1990 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,033 | $0 | Not Implemented |
WI0083 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $923 | $1,607 | Not Implemented |
WI0083 # 05 Y:1990 | 05 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,409 | $4,908 | Not Implemented |
WI0083 # 06 Y:1990 | 06 | 1990 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $1,655 | $2,000 | Not Implemented |
WI0083 # 07 Y:1990 | 07 | 1990 | INSTALL SET-BACK TIMERS | $338 | $200 | Not Implemented |
WI0083 # 08 Y:1990 | 08 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $210 | $1,000 | Not Implemented |
UD0233 # 01 Y:1987 | 01 | 1987 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,942 | $3,000 | Implemented |
UD0233 # 02 Y:1987 | 02 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,036 | $0 | Implemented |
UD0233 # 03 Y:1987 | 03 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $450 | $0 | Implemented |
CO0034 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,095 | $250 | Implemented |
CO0034 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $963 | $1,000 | Not Implemented |
CO0034 # 03 Y:1985 | 03 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,043 | $4,000 | Implemented |
CO0034 # 04 Y:1985 | 04 | 1985 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $327 | $200 | Implemented |
CO0034 # 05 Y:1985 | 05 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $250 | $100 | Not Implemented |
CO0034 # 06 Y:1985 | 06 | 1985 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $888 | $200 | Not Implemented |
CO0034 # 07 Y:1985 | 07 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $298 | $600 | Implemented |
CO0034 # 08 Y:1985 | 08 | 1985 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $231 | $300 | Implemented |
CO0034 # 09 Y:1985 | 09 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $4,196 | $100 | Implemented |
CO0034 # 10 Y:1985 | 10 | 1985 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $994 | $100 | Not Implemented |
CO0034 # 11 Y:1985 | 11 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,434 | $596 | Implemented |
ST0021 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,268 | $160 | Implemented |
ST0021 # 02 Y:1985 | 02 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $327 | $0 | Not Implemented |
ST0021 # 03 Y:1985 | 03 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $882 | $537 | Implemented |
ST0021 # 04 Y:1985 | 04 | 1985 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $455 | $0 | Implemented |