Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,673
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0619 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $816 | $878 | Not Implemented |
OK0619 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,184 | $200 | Implemented |
OK0619 # 05 Y:2001 | 05 | 2001 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,191 | $1,423 | Not Implemented |
OK0619 # 06 Y:2001 | 06 | 2001 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $38,340 | $12,500 | Not Implemented |
OK0619 # 07 Y:2001 | 07 | 2001 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $68,500 | $15,000 | Implemented |
OK0619 # 08 Y:2001 | 08 | 2001 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,200 | $1,326 | Implemented |
OK0619 # 09 Y:2001 | 09 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,082 | $3,936 | Not Implemented |
OK0619 # 10 Y:2001 | 10 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $12,577 | $3,000 | Implemented |
OK0619 # 11 Y:2001 | 11 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $11,523 | $10,275 | Implemented |
OK0619 # 12 Y:2001 | 12 | 2001 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $29,565 | $10,000 | Not Implemented |
OK0619 # 13 Y:2001 | 13 | 2001 | PAY BILLS ON TIME TO AVOID LATE FEES | $877 | $0 | Implemented |
WV0224 # 01 Y:2001 | 01 | 2001 | INCREASE AMOUNT OF CONDENSATE RETURNED | $34,989 | $13,233 | Implemented |
WV0224 # 02 Y:2001 | 02 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,320 | $5,782 | Not Implemented |
WV0224 # 03 Y:2001 | 03 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,209 | $1,000 | Not Implemented |
WV0224 # 04 Y:2001 | 04 | 2001 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $3,489 | $2,436 | Implemented |
WV0224 # 05 Y:2001 | 05 | 2001 | INSULATE BARE EQUIPMENT | $1,215 | $583 | Implemented |
WV0224 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $1,103 | $120 | Implemented |
WV0224 # 07 Y:2001 | 07 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $13,668 | $2,160 | Implemented |
WV0224 # 08 Y:2001 | 08 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,361 | $2,160 | Implemented |
WV0224 # 09 Y:2001 | 09 | 2001 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $8,176 | $31,000 | Not Implemented |
WV0224 # 10 Y:2001 | 10 | 2001 | RECYCLE WHITE WATER | $4,614 | $1,767 | Not Implemented |
WV0224 # 11 Y:2001 | 11 | 2001 | RECOVER AND REUSE COOLING WATER | $25,740 | $89,000 | Implemented |
WV0224 # 12 Y:2001 | 12 | 2001 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $20,000 | $14,000 | Not Implemented |
WV0224 # 13 Y:2001 | 13 | 2001 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $100,800 | $19,200 | Not Implemented |
UU0012 # 01 Y:2001 | 01 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $23,054 | $55,276 | Not Implemented |