IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,496

matching recommendations
Reset
SIC 28 Chemicals And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0021 # 08 Y:1991 08 1991 RECOVER WASTE HEAT FROM EQUIPMENT $12,180 $1,760 Implemented
AS0021 # 09 Y:1991 09 1991 IMPROVE LUBRICATION PRACTICES $7,796 $0 Implemented
AS0021 # 10 Y:1991 10 1991 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,246 $18,000 Implemented
AS0021 # 11 Y:1991 11 1991 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST $101,612 $1,050,000 Implemented
OR0108 # 01 Y:1991 01 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $615 $0 Implemented
OR0108 # 02 Y:1991 02 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,129 $500 Implemented
OR0108 # 03 Y:1991 03 1991 INSULATE BARE EQUIPMENT $2,482 $4,030 Implemented
OR0108 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $407 $0 Implemented
OR0108 # 05 Y:1991 05 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $21 $60 Implemented
KU0331 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $628 $395 Not Implemented
KU0331 # 02 Y:1991 02 1991 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $181 $500 Not Implemented
KU0331 # 03 Y:1991 03 1991 INSTALL SET-BACK TIMERS $2,630 $2,500 Not Implemented
KU0331 # 04 Y:1991 04 1991 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $3,445 $10,200 Not Implemented
KU0331 # 05 Y:1991 05 1991 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,394 $6,500 Not Implemented
KU0331 # 06 Y:1991 06 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,020 $0 Not Implemented
KU0331 # 07 Y:1991 07 1991 RECOVER WASTE HEAT FROM EQUIPMENT $5,925 $14,000 Not Implemented
KU0331 # 08 Y:1991 08 1991 IMPROVE LUBRICATION PRACTICES $793 $0 Not Implemented
OK0327 # 01 Y:1990 01 1990 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM $10,526 $2,150 Implemented
OK0327 # 02 Y:1990 02 1990 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $2,335 $5,076 Not Implemented
OK0327 # 03 Y:1990 03 1990 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $28,082 $13,087 Implemented
OK0327 # 04 Y:1990 04 1990 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $7,590 $4,484 Not Implemented
OK0327 # 05 Y:1990 05 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,932 $3,700 Implemented
OK0327 # 06 Y:1990 06 1990 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $63,353 $244,600 Not Implemented
OK0327 # 07 Y:1990 07 1990 INSTALL SET-BACK TIMERS $1,894 $650 Implemented
OK0327 # 08 Y:1990 08 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,670 $17,150 Implemented