Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
382
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0247 # 01 Y:2006 | 01 | 2006 | REPLACE BOILER | $115,080 | $223,000 | Not Implemented |
LE0247 # 07 Y:2006 | 07 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,225 | $1,152 | Implemented |
LE0247 # 06 Y:2006 | 06 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,646 | $2,500 | Implemented |
LE0247 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $1,181 | $300 | Not Implemented |
LE0247 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,912 | $3,722 | Not Implemented |
OK0737 # 05 Y:2006 | 05 | 2006 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $28,248 | $15,000 | Not Implemented |
OK0737 # 04 Y:2006 | 04 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $30,440 | $19,260 | Not Implemented |
OK0737 # 03 Y:2006 | 03 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $92,687 | $1,025 | Not Implemented |
OK0737 # 02 Y:2006 | 02 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $7,798 | $11,625 | Not Implemented |
OK0737 # 01 Y:2006 | 01 | 2006 | USE MINIMUM STEAM OPERATING PRESSURE | $22,707 | $1,420 | Not Implemented |
LL0252 # 08 Y:2006 | 08 | 2006 | INSULATE BARE EQUIPMENT | $76 | $79 | Implemented |
LL0252 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $182 | $120 | Not Implemented |
LL0252 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $886 | $525 | Implemented |
LL0252 # 05 Y:2006 | 05 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,064 | $159 | Not Implemented |
LL0252 # 04 Y:2006 | 04 | 2006 | TURN OFF STEAM TRACING DURING MILD WEATHER | $1,157 | $170 | Implemented |
LL0252 # 03 Y:2006 | 03 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,298 | $240 | Not Implemented |
LL0252 # 02 Y:2006 | 02 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $21,878 | $4,680 | Implemented |
LL0252 # 01 Y:2006 | 01 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $91,633 | $1,740 | Implemented |
MA0608 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $1,575 | $2,925 | Implemented |
MA0608 # 08 Y:2006 | 08 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $712 | $1,500 | Implemented |
MA0608 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,784 | $150 | Implemented |
MA0608 # 05 Y:2006 | 05 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,181 | $83,000 | Not Implemented |
MA0608 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $15,294 | $36,000 | Implemented |
MA0608 # 03 Y:2006 | 03 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $20,310 | $45,000 | Not Implemented |
MA0608 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,557 | $91,980 | Implemented |