Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
405
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0047 # 09 Y:2010 | 09 | 2010 | INSTALL OCCUPANCY SENSORS | $6,528 | $760 | Implemented |
MZ0047 # 08 Y:2010 | 08 | 2010 | INSULATE BARE EQUIPMENT | $225 | $360 | Implemented |
MZ0047 # 07 Y:2010 | 07 | 2010 | INSULATE BARE EQUIPMENT | $785 | $400 | Implemented |
MZ0047 # 06 Y:2010 | 06 | 2010 | INSULATE BARE EQUIPMENT | $929 | $2,160 | Implemented |
MZ0047 # 05 Y:2010 | 05 | 2010 | INSULATE BARE EQUIPMENT | $65 | $180 | Implemented |
MZ0047 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,818 | $20,818 | Implemented |
MZ0047 # 03 Y:2010 | 03 | 2010 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $5,857 | $80,000 | Not Implemented |
MZ0047 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,170 | $1,300 | Implemented |
MZ0047 # 01 Y:2010 | 01 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,104 | $3,000 | Implemented |
MZ0042 # 05 Y:2009 | 05 | 2009 | CONDENSE OPERATION INTO ONE BUILDING | $543,300 | $150,000 | Implemented |
MZ0042 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,970 | $214,200 | Not Implemented |
MZ0042 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $905 | $905 | Not Implemented |
MZ0042 # 02 Y:2009 | 02 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $19,660 | $18,000 | Not Implemented |
MZ0042 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,975 | $4,500 | Not Implemented |
MZ0020 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,500 | $0 | Implemented |
MZ0020 # 06 Y:2008 | 06 | 2008 | CONSOLIDATE FREIGHT SHIPMENTS AND/OR DELIVERIES | $7,280 | $0 | Implemented |
MZ0020 # 05 Y:2008 | 05 | 2008 | INSTALL OCCUPANCY SENSORS | $118 | $700 | Not Implemented |
MZ0020 # 04 Y:2008 | 04 | 2008 | INSTALL OCCUPANCY SENSORS | $127 | $570 | Implemented |
MZ0020 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $222 | $910 | Implemented |
MZ0020 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $702 | $2,210 | Implemented |
MZ0020 # 01 Y:2008 | 01 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,223 | $900 | Implemented |
MZ0003 # 06 Y:2007 | 06 | 2007 | ADD AREA LIGHTING SWITCHES | $3,995 | $500 | Not Implemented |
MZ0003 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $5,992 | $2,950 | Not Implemented |
MZ0003 # 04 Y:2007 | 04 | 2007 | DISCONNECT BALLASTS | $45,032 | $4,012 | Not Implemented |
MZ0003 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,859 | $30,000 | Not Implemented |