Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
219
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0237 # 02 Y:1999 | 02 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20,280 | $81,187 | Not Implemented |
UF0237 # 03 Y:1999 | 03 | 1999 | REDESIGN PROCESS | $418,000 | $141,700 | Not Implemented |
UF0237 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,848 | $2,526 | Not Implemented |
UF0237 # 04 Y:1999 | 04 | 1999 | ADOPT IN-HOUSE MATERIAL GENERATION | $1,357,000 | $6,200,000 | Not Implemented |
MS0148 # 03 Y:1999 | 03 | 1999 | USE PHOTOCELL CONTROLS | $2,140 | $1,195 | Not Implemented |
MS0148 # 02 Y:1999 | 02 | 1999 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,778 | $792 | Not Implemented |
MS0148 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,990 | $30,779 | Not Implemented |
MS0148 # 07 Y:1999 | 07 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,552 | $18,900 | Not Implemented |
MS0148 # 08 Y:1999 | 08 | 1999 | BURN WASTE OIL FOR HEAT | $614 | $2,274 | Not Implemented |
MS0148 # 10 Y:1999 | 10 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $13,641 | $2,100 | Implemented |
MS0148 # 04 Y:1999 | 04 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $374 | $222 | Not Implemented |
MS0148 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,282 | $2,577 | Not Implemented |
MS0148 # 09 Y:1999 | 09 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $12,122 | $100 | Implemented |
MS0148 # 05 Y:1999 | 05 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,136 | $1,500 | Implemented |
UF0235 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,565 | $69,897 | Not Implemented |
GT0679 # 04 Y:1999 | 04 | 1999 | INSULATE FEEDWATER TANK | $4,877 | $5,350 | Implemented |
GT0679 # 05 Y:1999 | 05 | 1999 | CLOSE OFF UNNEEDED STEAM LINES | $164 | $50 | Implemented |
GT0679 # 01 Y:1999 | 01 | 1999 | COMBINE UTILITY METERS | $1,400 | $0 | Not Implemented |
UF0235 # 03 Y:1999 | 03 | 1999 | ADOPT IN-HOUSE MATERIAL GENERATION | $2,190,000 | $8,100,000 | Not Implemented |
GT0679 # 07 Y:1999 | 07 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $5,625 | $14,270 | Not Implemented |
UF0235 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,200,000 | $17,000,000 | Not Implemented |
GT0679 # 02 Y:1999 | 02 | 1999 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $27,261 | $5,000 | Not Implemented |
GT0679 # 03 Y:1999 | 03 | 1999 | REPAIR AND ELIMINATE STEAM LEAKS | $1,157 | $200 | Implemented |
GT0679 # 06 Y:1999 | 06 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,006 | $46,917 | Not Implemented |
SF0179 # 07 Y:1999 | 07 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $6,334 | $8,650 | Not Implemented |