Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Georgia Institute of Technology |
---|---|
Assessment Year | 1999 |
Principal Product | Acrylic,Latex,& Coatings |
NAICS | n/a |
SIC | 2891 - Adhesives And Sealants |
Sales | $1,000,000-$5,000,000 |
# of Employees | 11 |
Plant Area (Sq.Ft.) | 45,000 |
Annual Production | 542 Thousand Gallons |
Production Hrs. Annual | 6,000 |
Location (State) | GA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $43,241 | 1,806,858 | kWh | $0.02 |
Electricity Demand | $21,406 | 5,409 | kW-months/year | $3.96 |
Electricity Fees | $7,183 | - | $ | - |
Natural Gas | $87,374 | 17,364 | MMBtu | $5.03 |
TOTAL ENERGY COSTS | $159,204 | |||
RECOMMENDED SAVINGS* | $47,490 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,198 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes | Administrative Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8112 COMBINE UTILITY METERS |
Savings: $1,400 Cost: - |
- | - | - | - | - | - | - | - | - | - | $1,400 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
$1,400 - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1333 CONVERT COMBUSTION EQUIPMENT TO BURN OIL |
Savings: $27,261 Cost: $5,000 |
- | - | - | - | $79,206 | 16,502 | $(-51,945) | (-16,502) | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$79,206 16,502 MMBtu |
$(-51,945) (-16,502) MMBtu |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $1,157 Cost: $200 |
- | - | - | - | - | - | $1,130 | 278 | - | - | - | - | $27 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$1,130 278 MMBtu |
- - $ |
- - $ |
$27 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2123 INSULATE FEEDWATER TANK |
Savings: $4,877 Cost: $5,350 |
- | - | - | - | - | - | $4,877 | 1,584 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,877 1,584 MMBtu |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2153 CLOSE OFF UNNEEDED STEAM LINES |
Savings: $164 Cost: $50 |
- | - | - | - | - | - | $164 | 52 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$164 52 MMBtu |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,006 Cost: $46,917 |
$4,436 | 184,642 | $2,570 | 642 | - | - | - | - | - | - | - | - | - | - |
$4,436 184,642 kWh |
$2,570 642 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $5,625 Cost: $14,270 |
- | - | - | - | - | - | - | - | $5,625 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$5,625 - $ |
- - $ |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $47,490 Cost: $71,787 |
$4,436 | 184,642 | $2,570 | 642 | $79,206 | 16,502 | $(-45,774) | (-14,588) | $5,625 | - | $1,400 | - | $27 | - | $4,436 184,642 kWh |
$2,570 642 kW-months/year |
$79,206 16,502 MMBtu |
$(-45,774) (-14,588) MMBtu |
$5,625 - $ |
$1,400 - $ |
$27 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,198 Cost: $5,600 |
- | - | - | - | - | - | $6,171 | 1,914 | - | - | - | - | $27 | - | - - kWh |
- - kW-months/year |
- - MMBtu |
$6,171 1,914 MMBtu |
- - $ |
- - $ |
$27 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes | Administrative Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes | Administrative Changes | Water Consumption |