Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
53
matching recommendationsSIC | 282 | Plastics Materials And Synthetics |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0475 # 03 Y:2004 | 03 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,390 | $500 | Implemented |
AM0475 # 04 Y:2004 | 04 | 2004 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $5,170 | $4,600 | Not Implemented |
AM0475 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,100 | $300 | Implemented |
AM0475 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,020 | $33 | Implemented |
AM0475 # 07 Y:2004 | 07 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,290 | $400 | Not Implemented |
AM0475 # 10 Y:2004 | 10 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,740 | $425 | Implemented |
AM0420 # 08 Y:2002 | 08 | 2002 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $2,500 | $150 | Implemented |
AM0420 # 01 Y:2002 | 01 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $656,000 | $3,400,000 | n/a |
AM0420 # 02 Y:2002 | 02 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $58,000 | $52,000 | Not Implemented |
AM0420 # 03 Y:2002 | 03 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $58,000 | $0 | Implemented |
AM0420 # 04 Y:2002 | 04 | 2002 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $49,000 | $0 | Not Implemented |
AM0420 # 05 Y:2002 | 05 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,200 | $0 | Not Implemented |
AM0420 # 06 Y:2002 | 06 | 2002 | REPAIR OR REPLACE STEAM TRAPS | $3,300 | $900 | Implemented |
AM0420 # 07 Y:2002 | 07 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,000 | $1,800 | Not Implemented |
AM0420 # 09 Y:2002 | 09 | 2002 | USE PHOTOCELL CONTROLS | $1,500 | $2,300 | Implemented |
AM0420 # 10 Y:2002 | 10 | 2002 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $700 | $0 | Implemented |
AM0403 # 11 Y:2001 | 11 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $900 | $0 | Implemented |
AM0403 # 09 Y:2001 | 09 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,380 | $2,640 | Implemented |
AM0403 # 08 Y:2001 | 08 | 2001 | MINIMIZE WATER USAGE | $4,500 | $5,100 | Not Implemented |
AM0403 # 07 Y:2001 | 07 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $7,050 | $5,890 | Implemented |
AM0403 # 06 Y:2001 | 06 | 2001 | INCREASE AMOUNT OF CONDENSATE RETURNED | $16,000 | $4,200 | Implemented |
AM0403 # 05 Y:2001 | 05 | 2001 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $10,730 | $0 | Implemented |
AM0403 # 04 Y:2001 | 04 | 2001 | USE SYNTHETIC LUBRICANT | $10,980 | $0 | Not Implemented |
AM0403 # 03 Y:2001 | 03 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,290 | $0 | Not Implemented |
AM0403 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $30,400 | $1,770 | Implemented |