Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
59
matching recommendationsSIC | 2821 | Plastics Materials And Resins |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0184 # 07 Y:2020 | 07 | 2020 | INSULATE BARE EQUIPMENT | $800 | $95 | Not Implemented |
DL0184 # 10 Y:2020 | 10 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,390 | $3,079 | Implemented |
DL0184 # 09 Y:2020 | 09 | 2020 | USE CONTINUOUS EQUIPMENT WHICH RETAINS PROCESS HEATING CONVEYORS WITHIN THE HEATED CHAMBER | $240 | $40 | Not Implemented |
DL0184 # 08 Y:2020 | 08 | 2020 | INSULATE BARE EQUIPMENT | $2,680 | $152 | Not Implemented |
DL0184 # 11 Y:2020 | 11 | 2020 | REDUCE VENTILATION AIR | $940 | $0 | Implemented |
DL0184 # 01 Y:2020 | 01 | 2020 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,702 | $0 | Not Implemented |
DL0184 # 03 Y:2020 | 03 | 2020 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $41,700 | $6,337 | Not Implemented |
DL0184 # 04 Y:2020 | 04 | 2020 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,170 | $4,250 | Not Implemented |
DL0184 # 05 Y:2020 | 05 | 2020 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9,500 | $1,400 | Not Implemented |
DL0184 # 06 Y:2020 | 06 | 2020 | INSULATE BARE EQUIPMENT | $4,400 | $4,750 | Not Implemented |
DL0184 # 12 Y:2020 | 12 | 2020 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,215 | $400 | Implemented |
DL0184 # 02 Y:2020 | 02 | 2020 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $22,300 | $15,661 | Implemented |
DL0174 # 04 Y:2017 | 04 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,550 | $8,000 | Not Implemented |
DL0174 # 09 Y:2017 | 09 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,220 | $34,080 | Not Implemented |
DL0174 # 08 Y:2017 | 08 | 2017 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $630 | $2,000 | Not Implemented |
DL0174 # 06 Y:2017 | 06 | 2017 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $10,800 | $0 | Not Implemented |
DL0174 # 07 Y:2017 | 07 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,500 | $25,000 | Not Implemented |
DL0174 # 05 Y:2017 | 05 | 2017 | ISOLATE STEAM LINES TO AVOID HEATING AIR CONDITIONED AREAS | $5,100 | $10,000 | Not Implemented |
DL0174 # 02 Y:2017 | 02 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,710 | $18,000 | Not Implemented |
DL0174 # 01 Y:2017 | 01 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,170 | $4,000 | Not Implemented |
DL0174 # 03 Y:2017 | 03 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,810 | $6,000 | Not Implemented |
DL0128 # 05 Y:2014 | 05 | 2014 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $6,000 | $20,000 | Implemented |
DL0128 # 04 Y:2014 | 04 | 2014 | INSULATE BARE EQUIPMENT | $18,200 | $12,560 | Implemented |
DL0128 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,150 | $101,600 | Implemented |
DL0128 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $59,000 | $150,000 | Implemented |