Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

64

matching recommendations
Reset
SIC 2821 Plastics Materials And Resins
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0534 # 08 Y:2008 08 2008 INSTALL OCCUPANCY SENSORS $1,219 $2,510 Implemented
OR0534 # 07 Y:2008 07 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $127 $125 Not Implemented
OR0534 # 06 Y:2008 06 2008 UPGRADE CONTROLS ON COMPRESSORS $1,203 $0 Not Implemented
OR0534 # 05 Y:2008 05 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $271 $0 Implemented
OR0534 # 04 Y:2008 04 2008 OPTIMIZE PLANT POWER FACTOR $6,768 $6,825 Implemented
OR0534 # 03 Y:2008 03 2008 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $6,794 $0 Implemented
OR0534 # 02 Y:2008 02 2008 REPLACE DC EQUIPMENT WITH AC EQUIPMENT $7,700 $167,953 Not Implemented
OR0532 # 06 Y:2008 06 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $1,195 $0 Not Implemented
OR0532 # 05 Y:2008 05 2008 OPTIMIZE PLANT POWER FACTOR $13,750 $20,650 Not Implemented
OR0532 # 04 Y:2008 04 2008 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $27,532 $49,504 Not Implemented
OR0532 # 03 Y:2008 03 2008 INSTALL OCCUPANCY SENSORS $4,068 $13,244 Not Implemented
OR0532 # 02 Y:2008 02 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,101 $2,697 Not Implemented
OR0532 # 01 Y:2008 01 2008 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $4,033 $400 Not Implemented
OR0363 # 03 Y:2000 03 2000 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL $3,600 $11,610 Not Implemented
OR0363 # 02 Y:2000 02 2000 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $14,790 $8,100 Not Implemented
OR0363 # 01 Y:2000 01 2000 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $15,630 $60,000 Not Implemented
OR0206 # 02 Y:1994 02 1994 RECOVER WASTE HEAT FROM EQUIPMENT $2,050 $2,746 Not Implemented
OR0206 # 01 Y:1994 01 1994 KEEP BOILER TUBES CLEAN $4,250 $1,000 Implemented
OR0206 # 03 Y:1994 03 1994 USE PHOTOCELL CONTROLS $5,147 $1,105 Implemented
OR0206 # 04 Y:1994 04 1994 USE POWER DURING OFF-PEAK PERIODS $42,700 $3,000 Not Implemented
OR0206 # 06 Y:1994 06 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $373 $825 Implemented
OR0206 # 07 Y:1994 07 1994 OPTIMIZE PLANT POWER FACTOR $4,297 $4,400 Not Implemented
OR0206 # 08 Y:1994 08 1994 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $16,148 $43,000 Implemented
OR0206 # 05 Y:1994 05 1994 INSTALL SET-BACK TIMERS $1,675 $600 Not Implemented
OR0063 # 04 Y:1989 04 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,306 $952 Not Implemented