Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsSIC | 2834 | Pharmaceutical Preparations |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0449 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $1,884 | $1,676 | Implemented |
UF0449 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,832 | $5,165 | Not Implemented |
UF0449 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $853 | $482 | Implemented |
UF0449 # 02 Y:2011 | 02 | 2011 | INSTALL COMMON HEADER ON COMPRESSORS | $138 | $280 | Not Implemented |
UF0449 # 01 Y:2011 | 01 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $493 | $0 | Implemented |
UF0449 # 06 Y:2011 | 06 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $697 | $0 | Implemented |
UF0449 # 07 Y:2011 | 07 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $3,726 | $1,919 | Not Implemented |
UF0449 # 11 Y:2011 | 11 | 2011 | USE OPTIMUM THICKNESS INSULATION | $1,450 | $576 | Not Implemented |
UF0449 # 08 Y:2011 | 08 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $2,799 | $7,128 | Not Implemented |
UF0449 # 09 Y:2011 | 09 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $659 | $686 | Implemented |
UF0449 # 10 Y:2011 | 10 | 2011 | AIR CONDITION ONLY SPACE NECESSARY | $227 | $21 | Implemented |
IC0185 # 02 Y:2011 | 02 | 2011 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $66,621 | $315,096 | n/a |
IC0185 # 07 Y:2011 | 07 | 2011 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $260,354 | $102,100 | n/a |
IC0185 # 06 Y:2011 | 06 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $205 | $334 | n/a |
IC0185 # 05 Y:2011 | 05 | 2011 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,057 | $115 | n/a |
IC0185 # 04 Y:2011 | 04 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $283 | $1 | n/a |
IC0185 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $604 | $1,719 | n/a |
IC0185 # 01 Y:2011 | 01 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $1,075 | $200 | Not Implemented |
MA0672 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,777 | $8,300 | Implemented |
MA0672 # 07 Y:2011 | 07 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,750 | $0 | Implemented |
MA0672 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,965 | $3,935 | Implemented |
MA0672 # 04 Y:2011 | 04 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,324 | $14,800 | Not Implemented |
MA0672 # 03 Y:2011 | 03 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,909 | $6,850 | Not Implemented |
MA0672 # 02 Y:2011 | 02 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,255 | $8,150 | Not Implemented |
MA0672 # 01 Y:2011 | 01 | 2011 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $128,581 | $1,577,500 | Not Implemented |