Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,141
matching recommendationsSIC | 2834 | Pharmaceutical Preparations |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0449 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,832 | $5,165 | Not Implemented |
UF0449 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $1,884 | $1,676 | Implemented |
UF0449 # 06 Y:2011 | 06 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $697 | $0 | Implemented |
UF0449 # 07 Y:2011 | 07 | 2011 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $3,726 | $1,919 | Not Implemented |
UF0449 # 08 Y:2011 | 08 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $2,799 | $7,128 | Not Implemented |
UF0449 # 09 Y:2011 | 09 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $659 | $686 | Implemented |
UF0449 # 10 Y:2011 | 10 | 2011 | AIR CONDITION ONLY SPACE NECESSARY | $227 | $21 | Implemented |
UF0449 # 11 Y:2011 | 11 | 2011 | USE OPTIMUM THICKNESS INSULATION | $1,450 | $576 | Not Implemented |
IC0185 # 01 Y:2011 | 01 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $1,075 | $200 | Not Implemented |
IC0185 # 02 Y:2011 | 02 | 2011 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $66,621 | $315,096 | n/a |
IC0185 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $604 | $1,719 | n/a |
IC0185 # 04 Y:2011 | 04 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $283 | $1 | n/a |
IC0185 # 05 Y:2011 | 05 | 2011 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,057 | $115 | n/a |
IC0185 # 06 Y:2011 | 06 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $205 | $334 | n/a |
IC0185 # 07 Y:2011 | 07 | 2011 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $260,354 | $102,100 | n/a |
MA0672 # 01 Y:2011 | 01 | 2011 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $128,581 | $1,577,500 | Not Implemented |
MA0672 # 02 Y:2011 | 02 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,255 | $8,150 | Not Implemented |
MA0672 # 03 Y:2011 | 03 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,909 | $6,850 | Not Implemented |
MA0672 # 04 Y:2011 | 04 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,324 | $14,800 | Not Implemented |
MA0672 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,965 | $3,935 | Implemented |
MA0672 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,777 | $8,300 | Implemented |
MA0672 # 07 Y:2011 | 07 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,750 | $0 | Implemented |
MS0371 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $930 | $386 | Not Implemented |
MS0371 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,866 | $2,431 | Not Implemented |
MS0371 # 03 Y:2011 | 03 | 2011 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,839 | $8,380 | Not Implemented |