Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
100
matching recommendationsSIC | 2834 | Pharmaceutical Preparations |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0224 # 02 Y:2001 | 02 | 2001 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $1,556 | $0 | n/a |
SF0224 # 01 Y:2001 | 01 | 2001 | INSTALL OCCUPANCY SENSORS | $9,345 | $540 | n/a |
SF0224 # 05 Y:2001 | 05 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $10,562 | $3,240 | n/a |
SF0224 # 06 Y:2001 | 06 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,146 | $2,800 | n/a |
SF0224 # 07 Y:2001 | 07 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $25,962 | $13,200 | n/a |
SF0224 # 08 Y:2001 | 08 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $11,660 | $9,500 | n/a |
SF0224 # 09 Y:2001 | 09 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,142 | $6,113 | n/a |
SF0224 # 10 Y:2001 | 10 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $259,156 | $256,500 | n/a |
SF0224 # 11 Y:2001 | 11 | 2001 | INSTALL OCCUPANCY SENSORS | $17,495 | $33,556 | n/a |
SF0224 # 12 Y:2001 | 12 | 2001 | OPTIMIZE PLANT POWER FACTOR | $120,158 | $160,000 | n/a |
SF0209 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $1,820 | $1,680 | Not Implemented |
SF0209 # 07 Y:2001 | 07 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $165 | $36 | Not Implemented |
SF0209 # 08 Y:2001 | 08 | 2001 | MINIMIZE WATER USAGE | $3,276 | $110 | Not Implemented |
SF0209 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $212 | $0 | Not Implemented |
SF0209 # 03 Y:2001 | 03 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,837 | $2,354 | Not Implemented |
SF0209 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,930 | $18,128 | Not Implemented |
SF0209 # 05 Y:2001 | 05 | 2001 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,184 | $4,100 | Not Implemented |
SF0209 # 06 Y:2001 | 06 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $357 | $1,508 | Not Implemented |
SD0252 # 01 Y:2000 | 01 | 2000 | INCREASE AMOUNT OF CONDENSATE RETURNED | $36,908 | $85,000 | Implemented |
SD0252 # 02 Y:2000 | 02 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $12,800 | $40,000 | Not Implemented |
SD0252 # 03 Y:2000 | 03 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $9,331 | $20,000 | Implemented |
SD0252 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,867 | $200 | Implemented |
SD0252 # 05 Y:2000 | 05 | 2000 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $4,167 | $10,200 | Implemented |
SD0252 # 06 Y:2000 | 06 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,692 | $1,500 | Implemented |
SD0252 # 07 Y:2000 | 07 | 2000 | INSTALL SKYLIGHTS | $70,269 | $5,536 | Implemented |