Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
129
matching recommendationsSIC | 2836 | Biological Products Exc. Diagnostic |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0062 # 07 Y:2010 | 07 | 2010 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,500 | $1,000 | Not Implemented |
DL0062 # 04 Y:2010 | 04 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,200 | $10,000 | Not Implemented |
DL0062 # 03 Y:2010 | 03 | 2010 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $10,000 | $6,300 | Not Implemented |
DL0062 # 02 Y:2010 | 02 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,000 | $15,930 | Not Implemented |
DL0062 # 01 Y:2010 | 01 | 2010 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $10,000 | $2,500 | Not Implemented |
DL0062 # 05 Y:2010 | 05 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,400 | $15,300 | Not Implemented |
DL0062 # 06 Y:2010 | 06 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,000 | $5,000 | Implemented |
DL0062 # 12 Y:2010 | 12 | 2010 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,700 | $10,000 | Not Implemented |
DL0062 # 08 Y:2010 | 08 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,900 | $30 | Implemented |
DL0062 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $649 | $1,331 | Not Implemented |
DL0062 # 10 Y:2010 | 10 | 2010 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $1,200 | $2,500 | Not Implemented |
DL0062 # 11 Y:2010 | 11 | 2010 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $2,800 | $10,000 | Not Implemented |
DL0062 # 13 Y:2010 | 13 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $233 | $970 | Not Implemented |
SU0300 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $828 | $883 | Not Implemented |
SU0300 # 05 Y:2010 | 05 | 2010 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $6,305 | $11,140 | Not Implemented |
SU0300 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $5,195 | $8,204 | Not Implemented |
SU0300 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,801 | $1,925 | Implemented |
SU0300 # 01 Y:2010 | 01 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $64,500 | $3,122 | Implemented |
SD0413 # 11 Y:2009 | 11 | 2009 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $1,764 | $1,725 | Not Implemented |
SD0413 # 09 Y:2009 | 09 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $25,825 | $17,794 | Not Implemented |
SD0413 # 12 Y:2009 | 12 | 2009 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $992 | $0 | Not Implemented |
SD0413 # 10 Y:2009 | 10 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,202 | $0 | Not Implemented |
SD0413 # 01 Y:2009 | 01 | 2009 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $151,192 | $1,125,000 | Not Implemented |
SD0413 # 02 Y:2009 | 02 | 2009 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $57,036 | $120,000 | Implemented |
SD0413 # 03 Y:2009 | 03 | 2009 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $31,920 | $13,200 | Implemented |