Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

108

matching recommendations
Reset
SIC 284 Soap, Cleaners, And Toilet Goods
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0736 # 04 Y:2006 04 2006 INSTALL / REPAIR INSULATION ON STEAM LINES $35,184 $14,041 Implemented
UD0736 # 05 Y:2006 05 2006 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $32,384 $28,000 Implemented
UD0736 # 06 Y:2006 06 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $29,264 $40,000 Implemented
UD0736 # 07 Y:2006 07 2006 INSULATE BARE EQUIPMENT $14,596 $6,878 Not Implemented
UD0736 # 08 Y:2006 08 2006 INSULATE FEEDWATER TANK $12,187 $6,825 Implemented
UD0736 # 09 Y:2006 09 2006 REPAIR OR REPLACE STEAM TRAPS $11,892 $240 Implemented
UD0736 # 10 Y:2006 10 2006 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $9,947 $15,000 Not Implemented
UD0736 # 11 Y:2006 11 2006 TREAT AND REUSE RINSE WATERS $9,788 $10,000 Not Implemented
UD0736 # 12 Y:2006 12 2006 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,612 $26,000 Implemented
UD0736 # 13 Y:2006 13 2006 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,098 $0 Implemented
UD0736 # 14 Y:2006 14 2006 UPGRADE CONTROLS ON COMPRESSORS $4,542 $0 Not Implemented
UD0736 # 15 Y:2006 15 2006 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,790 $0 Not Implemented
UD0736 # 16 Y:2006 16 2006 REPAIR AND ELIMINATE STEAM LEAKS $1,390 $2,800 Not Implemented
WV0224 # 01 Y:2001 01 2001 INCREASE AMOUNT OF CONDENSATE RETURNED $34,989 $13,233 Implemented
WV0224 # 02 Y:2001 02 2001 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,320 $5,782 Not Implemented
WV0224 # 03 Y:2001 03 2001 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,209 $1,000 Not Implemented
WV0224 # 04 Y:2001 04 2001 UTILIZE A LESS EXPENSIVE COOLING METHOD $3,489 $2,436 Implemented
WV0224 # 05 Y:2001 05 2001 INSULATE BARE EQUIPMENT $1,215 $583 Implemented
WV0224 # 06 Y:2001 06 2001 INSULATE BARE EQUIPMENT $1,103 $120 Implemented
WV0224 # 07 Y:2001 07 2001 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $13,668 $2,160 Implemented
WV0224 # 08 Y:2001 08 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $13,361 $2,160 Implemented
WV0224 # 09 Y:2001 09 2001 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $8,176 $31,000 Not Implemented
WV0224 # 10 Y:2001 10 2001 RECYCLE WHITE WATER $4,614 $1,767 Not Implemented
WV0224 # 11 Y:2001 11 2001 RECOVER AND REUSE COOLING WATER $25,740 $89,000 Implemented
WV0224 # 12 Y:2001 12 2001 $20,000 $14,000 Not Implemented