Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsSIC | 284 | Soap, Cleaners, And Toilet Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0173 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,747 | $191 | Implemented |
MS0173 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $635 | $2,618 | Not Implemented |
MS0173 # 04 Y:2000 | 04 | 2000 | USE PHOTOCELL CONTROLS | $240 | $222 | Not Implemented |
MS0173 # 05 Y:2000 | 05 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $238 | $236 | Implemented |
MS0173 # 06 Y:2000 | 06 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $206 | $65 | Not Implemented |
MS0173 # 07 Y:2000 | 07 | 2000 | INSULATE BARE EQUIPMENT | $169 | $381 | Not Implemented |
MS0173 # 08 Y:2000 | 08 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $831 | $599 | Not Implemented |
MS0173 # 09 Y:2000 | 09 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,488 | $50 | Implemented |
MS0173 # 10 Y:2000 | 10 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $11,932 | $50 | Implemented |
MS0173 # 11 Y:2000 | 11 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,514 | $50 | Not Implemented |
MS0173 # 01 Y:2000 | 01 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,872 | $1,710 | Not Implemented |
UD0598 # 03 Y:2000 | 03 | 2000 | INCREASE AMOUNT OF CONDENSATE RETURNED | $15,756 | $18,000 | Not Implemented |
UD0598 # 09 Y:2000 | 09 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,088 | $4,253 | Implemented |
UD0598 # 08 Y:2000 | 08 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $1,720 | $500 | Implemented |
UD0598 # 07 Y:2000 | 07 | 2000 | INSTALL OCCUPANCY SENSORS | $1,752 | $726 | Not Implemented |
UD0598 # 06 Y:2000 | 06 | 2000 | USE MINIMUM STEAM OPERATING PRESSURE | $3,333 | $0 | Implemented |
UD0598 # 05 Y:2000 | 05 | 2000 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $9,640 | $0 | Implemented |
UD0598 # 04 Y:2000 | 04 | 2000 | PURCHASE HIGH MATERIALS IN RETURNABLE BULK CONTAINERS | $13,603 | $0 | Not Implemented |
UD0598 # 02 Y:2000 | 02 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $22,073 | $34,288 | Implemented |
UD0598 # 01 Y:2000 | 01 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $1,210,579 | $375,000 | Not Implemented |
WI0361 # 01 Y:2000 | 01 | 2000 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $25,500 | $0 | Not Implemented |
WI0361 # 02 Y:2000 | 02 | 2000 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $14,677 | $45,000 | Not Implemented |
WI0361 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,555 | $1,380 | Not Implemented |
WI0361 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $984 | $3,740 | Implemented |
WI0361 # 05 Y:2000 | 05 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $894 | $0 | Not Implemented |