Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

225

matching recommendations
Reset
SIC 2841 Soap And Other Detergents
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0096 # 07 Y:1990 07 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $3,213 $70 Implemented
RU0096 # 08 Y:1990 08 1990 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $1,145 $373 Not Implemented
RU0096 # 09 Y:1990 09 1990 USE MINIMUM STEAM OPERATING PRESSURE $4,150 $0 Not Implemented
RU0043 # 01 Y:1988 01 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,773 $0 Implemented
RU0043 # 02 Y:1988 02 1988 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $6,546 $7,020 Not Implemented
RU0043 # 03 Y:1988 03 1988 IMPROVE LUBRICATION PRACTICES $298 $800 Implemented
RU0043 # 04 Y:1988 04 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,890 $678 Implemented
RU0043 # 05 Y:1988 05 1988 TURN OFF STEAM TRACING DURING MILD WEATHER $9,235 $0 Implemented
RU0043 # 06 Y:1988 06 1988 INSTALL TIMERS AND/OR THERMOSTATS $4,858 $1,195 Implemented
RU0043 # 07 Y:1988 07 1988 INSULATE BARE EQUIPMENT $2,812 $384 Implemented
RU0043 # 08 Y:1988 08 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $998 $500 Implemented
RU0011 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $181 $46 Implemented
RU0011 # 02 Y:1987 02 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,642 $7,500 Not Implemented
RU0011 # 03 Y:1987 03 1987 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $163 $330 Implemented
RU0011 # 04 Y:1987 04 1987 INSULATE BARE EQUIPMENT $5,588 $5,004 Not Implemented
MA0055 # 01 Y:1986 01 1986 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $20,099 $40,000 Not Implemented
MA0055 # 02 Y:1986 02 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $427 $34 Implemented
MA0055 # 03 Y:1986 03 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,032 $1,000 Implemented
UD0171 # 01 Y:1985 01 1985 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,352 $4,773 Implemented
UD0171 # 02 Y:1985 02 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $14,014 $17,000 Implemented
UD0171 # 03 Y:1985 03 1985 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $10,662 $38,000 Not Implemented
UD0171 # 04 Y:1985 04 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,744 $12,000 Not Implemented
UD0020 # 01 Y:1982 01 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $20,824 $30,000 Implemented
UD0020 # 02 Y:1982 02 1982 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $430 $300 Implemented
UD0020 # 03 Y:1982 03 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $138 $350 Not Implemented