Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

745

matching recommendations
Reset
SIC 2851 Paints And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WM0130 # 05 Y:2019 05 2019 OPTIMIZE PLANT POWER FACTOR $2,616 $3,000 Not Implemented
WM0130 # 06 Y:2019 06 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,815 $4,154 Not Implemented
WM0130 # 07 Y:2019 07 2019 USE SYNTHETIC LUBRICANT $1,417 $497 Not Implemented
WM0130 # 08 Y:2019 08 2019 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,212 $800 Not Implemented
WM0130 # 09 Y:2019 09 2019 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $705 $315 Not Implemented
WM0130 # 10 Y:2019 10 2019 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $698 $1,050 Not Implemented
WM0130 # 11 Y:2019 11 2019 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $597 $1,513 Not Implemented
WM0130 # 12 Y:2019 12 2019 USE PHOTOCELL CONTROLS $175 $404 Not Implemented
WM0130 # 13 Y:2019 13 2019 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $154 $255 Not Implemented
MI0334 # 11 Y:2018 11 2018 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $592 $1,973 Implemented
MI0334 # 10 Y:2018 10 2018 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $803 $1,560 Implemented
MI0334 # 09 Y:2018 09 2018 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $816 $1,980 Not Implemented
MI0334 # 08 Y:2018 08 2018 REDUCE DELIVERY SCHEDULES $1,454 $2,490 Implemented
MI0334 # 01 Y:2018 01 2018 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,234 $12,519 Not Implemented
MI0334 # 02 Y:2018 02 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,575 $13,838 Implemented
MI0334 # 03 Y:2018 03 2018 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,178 $2,030 Implemented
MI0334 # 04 Y:2018 04 2018 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,175 $6,578 Not Implemented
MI0334 # 05 Y:2018 05 2018 TURN OFF EQUIPMENT WHEN NOT IN USE $1,877 $1,300 Implemented
MI0334 # 06 Y:2018 06 2018 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,637 $3,750 Not Implemented
MI0334 # 07 Y:2018 07 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,564 $3,102 Implemented
OK0978 # 01 Y:2017 01 2017 OPTIMIZE PLANT POWER FACTOR $18,551 $40,582 Not Implemented
OK0978 # 02 Y:2017 02 2017 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,546 $20,000 Not Implemented
OK0978 # 03 Y:2017 03 2017 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,233 $2,000 Implemented
OK0978 # 04 Y:2017 04 2017 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $988 $4,800 Not Implemented
OK0978 # 05 Y:2017 05 2017 RECOVER WASTE HEAT FROM EQUIPMENT $7,833 $2,777 Not Implemented