Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 2851 | Paints And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0235 # 12 Y:1999 | 12 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $4,290 | $8,840 | Not Implemented |
SD0235 # 11 Y:1999 | 11 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $21,793 | $0 | Implemented |
SD0235 # 14 Y:1999 | 14 | 1999 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,362 | $1,078 | Implemented |
SD0235 # 10 Y:1999 | 10 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $107,143 | $115,000 | Not Implemented |
SD0235 # 09 Y:1999 | 09 | 1999 | RECYCLE CLEANING SOLVENT AND REUSE | $34,580 | $20,000 | Not Implemented |
SD0235 # 13 Y:1999 | 13 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $3,960 | $0 | Implemented |
SD0235 # 08 Y:1999 | 08 | 1999 | IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) | $594 | $0 | Not Implemented |
SD0235 # 07 Y:1999 | 07 | 1999 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $7,690 | $0 | Not Implemented |
SD0235 # 06 Y:1999 | 06 | 1999 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $3,794 | $14,000 | Not Implemented |
SD0235 # 05 Y:1999 | 05 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,852 | $0 | Not Implemented |
SD0235 # 04 Y:1999 | 04 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,218 | $23,830 | Implemented |
SD0235 # 03 Y:1999 | 03 | 1999 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,356 | $0 | Not Implemented |
SD0235 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,361 | $1,782 | Not Implemented |
SD0235 # 01 Y:1999 | 01 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,382 | $7,776 | Not Implemented |
SD0173 # 07 Y:1997 | 07 | 1997 | UPGRADE OBSOLETE EQUIPMENT | $1,145,482 | $644,000 | Implemented |
SD0173 # 06 Y:1997 | 06 | 1997 | CONVERT TO LESS TOXIC HYDROCARBON CLEANERS | $14,130 | $0 | Implemented |
SD0173 # 05 Y:1997 | 05 | 1997 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $46,200 | $100,000 | Not Implemented |
SD0173 # 04 Y:1997 | 04 | 1997 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,214 | $2,500 | Implemented |
SD0173 # 03 Y:1997 | 03 | 1997 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,910 | $500 | Implemented |
SD0173 # 02 Y:1997 | 02 | 1997 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $4,017 | $1,000 | Implemented |
SD0173 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,603 | $500 | Implemented |
SD0057 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,064 | $2,242 | Implemented |
SD0057 # 06 Y:1993 | 06 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,678 | $12,550 | Implemented |
SD0057 # 05 Y:1993 | 05 | 1993 | INSTALL SET-BACK TIMERS | $226 | $115 | Not Implemented |
SD0057 # 03 Y:1993 | 03 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,057 | $0 | Implemented |