Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
765
matching recommendationsSIC | 2869 | Industrial Organic Chemicals, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0432 # 05 Y:2010 | 05 | 2010 | USE PHOTOCELL CONTROLS | $6,416 | $768 | Not Implemented |
UF0432 # 06 Y:2010 | 06 | 2010 | INSTALL COMMON HEADER ON COMPRESSORS | $1,520 | $0 | Not Implemented |
UF0432 # 07 Y:2010 | 07 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,000 | $2,700 | Not Implemented |
UF0432 # 08 Y:2010 | 08 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $364 | $0 | Not Implemented |
UF0432 # 09 Y:2010 | 09 | 2010 | CLEAN CONDENSER TUBES | $1,343 | $120 | Not Implemented |
UF0432 # 10 Y:2010 | 10 | 2010 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $3,120 | $0 | Not Implemented |
UF0432 # 11 Y:2010 | 11 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,637 | $1,500 | Not Implemented |
MZ0042 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,975 | $4,500 | Not Implemented |
MZ0042 # 02 Y:2009 | 02 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $19,660 | $18,000 | Not Implemented |
MZ0042 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $905 | $905 | Not Implemented |
MZ0042 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,970 | $214,200 | Not Implemented |
MZ0042 # 05 Y:2009 | 05 | 2009 | CONDENSE OPERATION INTO ONE BUILDING | $543,300 | $150,000 | Implemented |
LL0307 # 01 Y:2009 | 01 | 2009 | INSULATE BARE EQUIPMENT | $8,550 | $1,841 | Implemented |
LL0307 # 02 Y:2009 | 02 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,776 | $6,070 | Not Implemented |
LL0307 # 03 Y:2009 | 03 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,201 | $64 | Not Implemented |
LL0307 # 04 Y:2009 | 04 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,773 | $870 | Implemented |
LL0307 # 05 Y:2009 | 05 | 2009 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,650 | $180 | Implemented |
LL0307 # 06 Y:2009 | 06 | 2009 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $2,164 | $45 | Not Implemented |
LL0307 # 07 Y:2009 | 07 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $948 | $10 | Not Implemented |
LL0307 # 08 Y:2009 | 08 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $518 | $40 | Implemented |
LL0307 # 09 Y:2009 | 09 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $414 | $312 | Not Implemented |
OK0773 # 01 Y:2009 | 01 | 2009 | OPERATE BOILERS ON HIGH FIRE SETTING | $14,770 | $22,000 | Not Implemented |
OK0773 # 02 Y:2009 | 02 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,800 | $0 | Implemented |
OK0773 # 03 Y:2009 | 03 | 2009 | REPAIR AND ELIMINATE STEAM LEAKS | $36,076 | $2,450 | Implemented |
OK0773 # 04 Y:2009 | 04 | 2009 | USE PHOTOCELL CONTROLS | $1,554 | $1,284 | Implemented |