Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
765
matching recommendationsSIC | 2869 | Industrial Organic Chemicals, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0410 # 09 Y:2007 | 09 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,380 | $280 | Implemented |
OK0749 # 01 Y:2007 | 01 | 2007 | MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT | $74,106 | $206,725 | Not Implemented |
OK0749 # 02 Y:2007 | 02 | 2007 | REDUCE EXCESSIVE BOILER BLOWDOWN | $66,275 | $21,000 | Not Implemented |
OK0749 # 03 Y:2007 | 03 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $126,819 | $38,280 | Not Implemented |
OK0749 # 04 Y:2007 | 04 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $93,609 | $4,680 | Not Implemented |
OK0749 # 05 Y:2007 | 05 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,286 | $1,985 | Not Implemented |
OK0749 # 06 Y:2007 | 06 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,461 | $0 | Implemented |
OK0749 # 07 Y:2007 | 07 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $181,080 | $110,352 | Not Implemented |
OK0749 # 08 Y:2007 | 08 | 2007 | OPERATE BOILERS ON HIGH FIRE SETTING | $238,762 | $50,000 | Not Implemented |
IC0125 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $202,850 | $475,200 | Not Implemented |
IC0125 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $305,019 | $900,000 | Not Implemented |
IC0125 # 03 Y:2007 | 03 | 2007 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $227,690 | $372,000 | Not Implemented |
IC0125 # 04 Y:2007 | 04 | 2007 | USE MINIMUM STEAM OPERATING PRESSURE | $611 | $0 | Implemented |
IC0125 # 05 Y:2007 | 05 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $36,000 | $0 | Not Implemented |
IC0125 # 06 Y:2007 | 06 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $21,910 | $4,260 | Not Implemented |
IC0125 # 07 Y:2007 | 07 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $25,485 | $4,800 | Implemented |
IC0125 # 08 Y:2007 | 08 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $12,731 | $18,755 | Not Implemented |
IC0125 # 09 Y:2007 | 09 | 2007 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $52,577 | $43,780 | Implemented |
IC0125 # 10 Y:2007 | 10 | 2007 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,975 | $14,767 | Not Implemented |
IC0125 # 11 Y:2007 | 11 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,961 | $16,278 | Implemented |
IC0125 # 12 Y:2007 | 12 | 2007 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,563 | $0 | Implemented |
NC0350 # 01 Y:2006 | 01 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $122,745 | $114,000 | Not Implemented |
NC0350 # 02 Y:2006 | 02 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,138 | $10,500 | Not Implemented |
NC0350 # 03 Y:2006 | 03 | 2006 | USE OPTIMUM THICKNESS INSULATION | $12,275 | $1,000 | Implemented |
NC0350 # 04 Y:2006 | 04 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,381 | $2,000 | Not Implemented |