Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
598
matching recommendationsSIC | 2891 | Adhesives And Sealants |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0084 # 07 Y:2016 | 07 | 2016 | INSTALL OCCUPANCY SENSORS | $4,032 | $9,450 | Not Implemented |
WM0084 # 08 Y:2016 | 08 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,103 | $400 | Implemented |
WM0084 # 09 Y:2016 | 09 | 2016 | INSULATE BARE EQUIPMENT | $1,819 | $409 | Not Implemented |
WM0084 # 10 Y:2016 | 10 | 2016 | USE SYNTHETIC LUBRICANT | $1,724 | $630 | Not Implemented |
WM0084 # 11 Y:2016 | 11 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,465 | $0 | Implemented |
WM0084 # 12 Y:2016 | 12 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $866 | $1,988 | Implemented |
WM0084 # 13 Y:2016 | 13 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $101 | $402 | Not Implemented |
WV0521 # 01 Y:2016 | 01 | 2016 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $26,401 | $25,760 | Not Implemented |
WV0521 # 02 Y:2016 | 02 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $10,186 | $8,000 | Implemented |
WV0521 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,543 | $2,714 | Not Implemented |
WV0521 # 04 Y:2016 | 04 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,142 | $152 | Implemented |
WV0521 # 05 Y:2016 | 05 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $2,423 | $1,224 | Not Implemented |
WV0521 # 06 Y:2016 | 06 | 2016 | INSULATE BARE EQUIPMENT | $1,612 | $3,592 | Not Implemented |
WV0521 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $728 | $443 | Implemented |
WV0521 # 08 Y:2016 | 08 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $718 | $500 | Implemented |
WV0521 # 09 Y:2016 | 09 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $408 | $728 | Not Implemented |
LE0409 # 01 Y:2016 | 01 | 2016 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $591 | $0 | Implemented |
LE0409 # 02 Y:2016 | 02 | 2016 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $2,416 | $2,000 | Implemented |
LE0409 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,598 | $5,700 | Implemented |
LE0409 # 04 Y:2016 | 04 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,605 | $43,760 | Not Implemented |
LE0409 # 05 Y:2016 | 05 | 2016 | USE RADIANT HEATER FOR SPOT HEATING | $6,148 | $21,000 | Implemented |
LE0409 # 06 Y:2016 | 06 | 2016 | USE SOLAR HEAT TO MAKE ELECTRICTY | $45,635 | $252,000 | Not Implemented |
SF0475 # 01 Y:2015 | 01 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,033 | $0 | Implemented |
SF0475 # 02 Y:2015 | 02 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,039 | $0 | Implemented |
SF0475 # 03 Y:2015 | 03 | 2015 | INSULATE BARE EQUIPMENT | $2,990 | $822 | Implemented |