Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsSIC | 2893 | Printing Ink |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NV0084 # 02 Y:1997 | 02 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,562 | $375 | Implemented |
NV0084 # 14 Y:1997 | 14 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $312 | $0 | Implemented |
NV0084 # 13 Y:1997 | 13 | 1997 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $437 | $120 | Implemented |
NV0084 # 12 Y:1997 | 12 | 1997 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $394 | $147 | Implemented |
NV0084 # 11 Y:1997 | 11 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $78 | $0 | Not Implemented |
NV0084 # 10 Y:1997 | 10 | 1997 | REGENERATE CLEANING SOLVENT ON-SITE AND REUSE | $3,712 | $5,025 | Not Implemented |
NV0084 # 09 Y:1997 | 09 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $920 | $150 | Not Implemented |
NV0084 # 08 Y:1997 | 08 | 1997 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $450 | $690 | Implemented |
NV0084 # 07 Y:1997 | 07 | 1997 | HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS | $102 | $0 | Implemented |
NV0084 # 06 Y:1997 | 06 | 1997 | USE OPTIMUM TEMPERATURE | $195 | $0 | Not Implemented |
NV0084 # 05 Y:1997 | 05 | 1997 | INSULATE BARE EQUIPMENT | $431 | $1,035 | Implemented |
NV0084 # 04 Y:1997 | 04 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $258 | $308 | Implemented |
NV0084 # 03 Y:1997 | 03 | 1997 | INSTALL OCCUPANCY SENSORS | $789 | $410 | Not Implemented |
NV0084 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,052 | $840 | Not Implemented |
TN0613 # 01 Y:1997 | 01 | 1997 | USE TEFLON LINED TANKS | $525,690 | $35,280 | Not Implemented |
TN0613 # 02 Y:1997 | 02 | 1997 | MODIFY STARTUP/SHUTDOWN TIMES | $39,000 | $17,200 | Implemented |
TN0613 # 03 Y:1997 | 03 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $35,000 | $22,200 | Not Implemented |
TN0613 # 04 Y:1997 | 04 | 1997 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $24,170 | $1,040 | Not Implemented |
TN0613 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,470 | $0 | Not Implemented |
TN0613 # 06 Y:1997 | 06 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $510 | $0 | Not Implemented |
TN0613 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $280 | $280 | Implemented |