Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
54
matching recommendationsSIC | 2899 | Chemical Preparations, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0280 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,020 | $0 | Not Implemented |
IA0280 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $845 | $668 | Not Implemented |
IA0280 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $604 | $1,592 | Not Implemented |
IA0280 # 05 Y:2001 | 05 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $87,600 | $7,916 | Implemented |
IA0280 # 06 Y:2001 | 06 | 2001 | REPAIR AND ELIMINATE STEAM LEAKS | $25,698 | $10,330 | Implemented |
IA0280 # 07 Y:2001 | 07 | 2001 | ADJUST BURNERS FOR EFFICIENT OPERATION | $4,493 | $7,500 | Not Implemented |
IA0280 # 08 Y:2001 | 08 | 2001 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $23,473 | $10,000 | Not Implemented |
IA0280 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,114 | $0 | Not Implemented |
SF0226 # 10 Y:2001 | 10 | 2001 | INSTALL OCCUPANCY SENSORS | $1,758 | $2,040 | Implemented |
SF0226 # 01 Y:2001 | 01 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,294 | $0 | Not Implemented |
SF0226 # 03 Y:2001 | 03 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $726 | $30 | Not Implemented |
SF0226 # 04 Y:2001 | 04 | 2001 | OPERATE BOILERS ON HIGH FIRE SETTING | $16,154 | $1,260 | Not Implemented |
SF0226 # 05 Y:2001 | 05 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $35,839 | $11,800 | Implemented |
SF0226 # 06 Y:2001 | 06 | 2001 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $844 | $535 | Implemented |
SF0226 # 07 Y:2001 | 07 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,016 | $3,275 | Implemented |
SF0226 # 08 Y:2001 | 08 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $3,717 | $2,500 | Implemented |
SF0226 # 09 Y:2001 | 09 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,944 | $14,649 | n/a |
SF0226 # 02 Y:2001 | 02 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,916 | $0 | Not Implemented |
SF0226 # 11 Y:2001 | 11 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $863 | $1,126 | Implemented |
SF0226 # 12 Y:2001 | 12 | 2001 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,217 | $8,000 | Not Implemented |
SF0226 # 13 Y:2001 | 13 | 2001 | INSTALL OCCUPANCY SENSORS | $8,563 | $24,267 | Not Implemented |
SF0226 # 14 Y:2001 | 14 | 2001 | SHIP HYDRAULIC OIL TO SECONDARY FUEL PROGRAM | $9,549 | $15,524 | Not Implemented |
LL0122 # 01 Y:2001 | 01 | 2001 | INSTALL SKYLIGHTS | $3,305 | $1,737 | Not Implemented |
LL0122 # 05 Y:2001 | 05 | 2001 | USE PHOTOCELL CONTROLS | $8,786 | $495 | Implemented |
LL0122 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,898 | $660 | Implemented |