Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

155

matching recommendations
Reset
SIC 291 Petroleum Refining
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UMS001 # 04 Y:2012 04 2012 ADJUST BURNERS FOR EFFICIENT OPERATION $13,000 $15,000 Not Implemented
UMS001 # 03 Y:2012 03 2012 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $938,000 $1,000,000 Not Implemented
UMS001 # 01 Y:2012 01 2012 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $986,100 $900,000 Not Implemented
UMS001 # 02 Y:2012 02 2012 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $782,000 $1,377,000 Not Implemented
WV0395 # 06 Y:2009 06 2009 USE PHOTOCELL CONTROLS $104,843 $11,000 Not Implemented
WV0395 # 02 Y:2009 02 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $169,299 $189,633 Not Implemented
WV0395 # 04 Y:2009 04 2009 INCREASE AMOUNT OF CONDENSATE RETURNED $114,898 $80,000 Not Implemented
WV0395 # 05 Y:2009 05 2009 USE MINIMUM STEAM OPERATING PRESSURE $113,873 $56,000 Not Implemented
WV0395 # 03 Y:2009 03 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $144,811 $1,000 Implemented
WV0395 # 01 Y:2009 01 2009 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $216,842 $130,000 Not Implemented
WV0395 # 08 Y:2009 08 2009 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $18,362 $1,925 Implemented
WV0395 # 09 Y:2009 09 2009 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,963 $1,941 Not Implemented
WV0395 # 07 Y:2009 07 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $26,253 $2,304 Implemented
WV0395 # 10 Y:2009 10 2009 INSTALL OCCUPANCY SENSORS $485 $300 Implemented
LL0253 # 04 Y:2006 04 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $169,857 $39,760 Implemented
LL0253 # 06 Y:2006 06 2006 INSULATE BARE EQUIPMENT $67,882 $10,319 Not Implemented
LL0253 # 07 Y:2006 07 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,598 $8,750 Not Implemented
LL0253 # 02 Y:2006 02 2006 REPAIR AND ELIMINATE STEAM LEAKS $658,473 $14,120 Implemented
LL0253 # 03 Y:2006 03 2006 REDUCE EXCESSIVE BOILER BLOWDOWN $177,541 $24,000 Not Implemented
LL0253 # 05 Y:2006 05 2006 USE PHOTOCELL CONTROLS $120,278 $11,880 Not Implemented
LL0253 # 01 Y:2006 01 2006 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL $4,994,000 $250,000 Not Implemented
LL0173 # 02 Y:2003 02 2003 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $1,828 $770 Not Implemented
LL0173 # 06 Y:2003 06 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $474 $15 Not Implemented
LL0173 # 04 Y:2003 04 2003 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $599 $158 Not Implemented
LL0173 # 05 Y:2003 05 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $583 $560 Not Implemented