Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
144
matching recommendationsSIC | 2911 | Petroleum Refining |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0395 # 06 Y:2009 | 06 | 2009 | USE PHOTOCELL CONTROLS | $104,843 | $11,000 | Not Implemented |
WV0395 # 04 Y:2009 | 04 | 2009 | INCREASE AMOUNT OF CONDENSATE RETURNED | $114,898 | $80,000 | Not Implemented |
WV0395 # 01 Y:2009 | 01 | 2009 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $216,842 | $130,000 | Not Implemented |
LL0253 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $67,882 | $10,319 | Not Implemented |
LL0253 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,598 | $8,750 | Not Implemented |
LL0253 # 03 Y:2006 | 03 | 2006 | REDUCE EXCESSIVE BOILER BLOWDOWN | $177,541 | $24,000 | Not Implemented |
LL0253 # 05 Y:2006 | 05 | 2006 | USE PHOTOCELL CONTROLS | $120,278 | $11,880 | Not Implemented |
LL0253 # 02 Y:2006 | 02 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $658,473 | $14,120 | Implemented |
LL0253 # 01 Y:2006 | 01 | 2006 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $4,994,000 | $250,000 | Not Implemented |
LL0253 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $169,857 | $39,760 | Implemented |
LL0173 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $583 | $560 | Not Implemented |
LL0173 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $571 | $420 | Not Implemented |
LL0173 # 09 Y:2003 | 09 | 2003 | INSTALL OCCUPANCY SENSORS | $106 | $130 | Not Implemented |
LL0173 # 02 Y:2003 | 02 | 2003 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,828 | $770 | Not Implemented |
LL0173 # 03 Y:2003 | 03 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,184 | $345 | Not Implemented |
LL0173 # 06 Y:2003 | 06 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $474 | $15 | Not Implemented |
LL0173 # 07 Y:2003 | 07 | 2003 | USE PHOTOCELL CONTROLS | $439 | $598 | Not Implemented |
LL0173 # 04 Y:2003 | 04 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $599 | $158 | Not Implemented |
LL0173 # 01 Y:2003 | 01 | 2003 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $10,856 | $4,436 | Not Implemented |
LL0166 # 08 Y:2003 | 08 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $55,292 | $0 | Implemented |
LL0166 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,855 | $9,440 | Implemented |
LL0166 # 01 Y:2003 | 01 | 2003 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $100,695 | $120,000 | Implemented |
LL0166 # 04 Y:2003 | 04 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,286 | $20 | Not Implemented |
LL0166 # 05 Y:2003 | 05 | 2003 | USE PHOTOCELL CONTROLS | $1,918 | $492 | Not Implemented |
LL0166 # 06 Y:2003 | 06 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $967 | $570 | Not Implemented |