IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

15

matching recommendations
Reset
SIC 295 Asphalt Paving And Roofing Materials
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0803 # 01 Y:2005 01 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,764 $944 Implemented
GT0803 # 02 Y:2005 02 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $11,058 $1,000 Implemented
GT0803 # 03 Y:2005 03 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,504 $7,500 Implemented
GT0803 # 04 Y:2005 04 2005 ADJUST BURNERS FOR EFFICIENT OPERATION $26,869 $3,000 Implemented
GT0803 # 05 Y:2005 05 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,965 $13,380 Not Implemented
GT0803 # 06 Y:2005 06 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $10,157 $27,000 Not Implemented
GT0803 # 07 Y:2005 07 2005 USE PHOTOCELL CONTROLS $2,516 $570 Implemented
GT0803 # 08 Y:2005 08 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $779 $695 Implemented
GT0803 # 09 Y:2005 09 2005 OPTIMIZE PLANT POWER FACTOR $17,969 $6,055 Not Implemented
GT0619 # 01 Y:1997 01 1997 RECOVER WASTE HEAT FROM EQUIPMENT $66,400 $60,620 Not Implemented
GT0619 # 02 Y:1997 02 1997 INCREASE AMOUNT OF CONDENSATE RETURNED $62,700 $18,000 Implemented
GT0619 # 03 Y:1997 03 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $990 $500 Implemented
GT0619 # 04 Y:1997 04 1997 INSULATE BARE EQUIPMENT $116 $310 Implemented
GT0619 # 05 Y:1997 05 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,050 $700 Not Implemented
GT0619 # 06 Y:1997 06 1997 USE RE-USABLE FILTERS $60,000 $8,000 Not Implemented