Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
500
matching recommendationsSIC | 2952 | Asphalt Felts And Coatings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0313 # 04 Y:2003 | 04 | 2003 | OPTIMIZE PLANT POWER FACTOR | $13,902 | $27,000 | Not Implemented |
UF0313 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $7,223 | $973 | Implemented |
UF0313 # 06 Y:2003 | 06 | 2003 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $19,080 | $34,976 | Not Implemented |
UF0313 # 07 Y:2003 | 07 | 2003 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $333,770 | $250,000 | Not Implemented |
UF0313 # 08 Y:2003 | 08 | 2003 | INSTALL BACK-UP EQUIPMENT | $57,960 | $109,500 | Implemented |
UF0313 # 09 Y:2003 | 09 | 2003 | INSTALL SYSTEM TO COLLECT SCRAP | $1,808 | $700 | Implemented |
OR0418 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,409 | $1,400 | Implemented |
OR0418 # 02 Y:2002 | 02 | 2002 | UPGRADE CONTROLS ON COMPRESSORS | $6,865 | $7,600 | Implemented |
OR0418 # 03 Y:2002 | 03 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,090 | $1,800 | Implemented |
OR0418 # 04 Y:2002 | 04 | 2002 | OPTIMIZE PLANT POWER FACTOR | $929 | $1,500 | Implemented |
OR0418 # 05 Y:2002 | 05 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,707 | $9,446 | Implemented |
SF0196 # 01 Y:2000 | 01 | 2000 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $648 | $860 | Implemented |
SF0196 # 02 Y:2000 | 02 | 2000 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $67 | $287 | Implemented |
SF0196 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,663 | $6,340 | Implemented |
SF0196 # 04 Y:2000 | 04 | 2000 | COMBINE UTILITY METERS | $1,738 | $60 | Implemented |
UF0231 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,328 | $4,141 | Not Implemented |
UF0231 # 02 Y:1999 | 02 | 1999 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,140 | $2,650 | Not Implemented |
UF0231 # 03 Y:1999 | 03 | 1999 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,596 | $450 | Implemented |
UF0231 # 04 Y:1999 | 04 | 1999 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $12,394 | $42,085 | Not Implemented |
UF0231 # 05 Y:1999 | 05 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,198 | $1,000 | Implemented |
UF0231 # 06 Y:1999 | 06 | 1999 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $62,712 | $2,200 | Not Implemented |
UF0231 # 07 Y:1999 | 07 | 1999 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,200 | $0 | Implemented |
UF0231 # 08 Y:1999 | 08 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,562 | $0 | Implemented |
AM0340 # 01 Y:1999 | 01 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $204,000 | $600,000 | Not Implemented |
AM0340 # 02 Y:1999 | 02 | 1999 | REPLACE BOILER | $89,600 | $70,000 | Not Implemented |