Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

315

matching recommendations
Reset
SIC 299 Misc. Petroleum And Coal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0023 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $2,370 $481 Not Implemented
UM0023 # 05 Y:1995 05 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $3,126 $1,990 Not Implemented
UM0023 # 06 Y:1995 06 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $3,012 $471 Not Implemented
KU0424 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $242 $3,578 Not Implemented
KU0424 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $667 $450 Not Implemented
KU0424 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $566 $1,534 Not Implemented
KU0424 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,757 $375 Not Implemented
KU0424 # 05 Y:1994 05 1994 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $556 $200 Not Implemented
KU0424 # 06 Y:1994 06 1994 REDUCE VENTILATION AIR $156 $0 Not Implemented
OK0425 # 01 Y:1994 01 1994 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $1,247,712 $4,815,000 Not Implemented
OK0425 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,846 $11,619 Implemented
OK0425 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,605 $0 Implemented
OK0425 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $467 $1,920 Not Implemented
WI0192 # 10 Y:1993 10 1993 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $314 $200 Not Implemented
WI0192 # 09 Y:1993 09 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,676 $0 Implemented
WI0192 # 08 Y:1993 08 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $265 $0 Not Implemented
WI0192 # 07 Y:1993 07 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,739 $1,753 Implemented
WI0192 # 06 Y:1993 06 1993 INSTALL OCCUPANCY SENSORS $482 $225 Implemented
WI0192 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $498 $1,063 Implemented
WI0192 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,334 $3,400 Implemented
WI0192 # 03 Y:1993 03 1993 INSULATE BARE EQUIPMENT $525 $314 Not Implemented
WI0192 # 02 Y:1993 02 1993 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $484 $1,000 Not Implemented
WI0192 # 01 Y:1993 01 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,147 $500 Implemented
KU0415 # 01 Y:1993 01 1993 REPAIR AND ELIMINATE STEAM LEAKS $1,558 $150 Implemented
KU0415 # 02 Y:1993 02 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $983 $2,255 Implemented