Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47
matching recommendationsSIC | 299 | Misc. Petroleum And Coal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0338 # 02 Y:2007 | 02 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,705 | $751 | Not Implemented |
BD0338 # 03 Y:2007 | 03 | 2007 | DISCONNECT BALLASTS | $2,472 | $241 | Not Implemented |
BD0338 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $509 | $2 | Not Implemented |
BD0338 # 05 Y:2007 | 05 | 2007 | USE SYNTHETIC LUBRICANT | $1,378 | $2 | Not Implemented |
BD0338 # 06 Y:2007 | 06 | 2007 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $369,530 | $30,001 | Not Implemented |
BD0338 # 07 Y:2007 | 07 | 2007 | REPLACE BOILER | $36,792 | $110,001 | Implemented |
BD0338 # 08 Y:2007 | 08 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $8,864 | $12,000 | Not Implemented |
BD0338 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,227 | $1,103 | Not Implemented |
UM0322 # 01 Y:2007 | 01 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $43,338 | $0 | Implemented |
UM0322 # 10 Y:2007 | 10 | 2007 | USE PHOTOCELL CONTROLS | $549 | $190 | Implemented |
UM0322 # 05 Y:2007 | 05 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,439 | $1,000 | Implemented |
UM0322 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $14,251 | $5,900 | Implemented |
UM0322 # 06 Y:2007 | 06 | 2007 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $2,752 | $3,415 | Not Implemented |
UM0322 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $913 | $600 | Implemented |
UM0322 # 09 Y:2007 | 09 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $560 | $1,815 | Not Implemented |
UM0322 # 07 Y:2007 | 07 | 2007 | REDUCE FLUID FLOW RATES | $1,434 | $2,200 | Not Implemented |
UM0322 # 03 Y:2007 | 03 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,446 | $890 | Not Implemented |
UM0322 # 04 Y:2007 | 04 | 2007 | INSULATE BARE EQUIPMENT | $6,308 | $6,013 | Implemented |
OR0517 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $35,400 | $7,000 | Implemented |
OR0517 # 04 Y:2007 | 04 | 2007 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $17,200 | $500 | Implemented |
OR0517 # 05 Y:2007 | 05 | 2007 | INCREASE USE OF AUTOMATION | $10,400 | $10,000 | Not Implemented |
OR0517 # 06 Y:2007 | 06 | 2007 | INSULATE BARE EQUIPMENT | $6,100 | $3,750 | Implemented |
OR0517 # 07 Y:2007 | 07 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $3,460 | $10,350 | Implemented |
OR0517 # 08 Y:2007 | 08 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $930 | $0 | Implemented |
OR0517 # 09 Y:2007 | 09 | 2007 | OPTIMIZE PLANT POWER FACTOR | $1,470 | $0 | Not Implemented |