IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

556

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0685 # 08 Y:2000 08 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $14,950 $4,740 Not Implemented
GT0680 # 01 Y:1999 01 1999 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $7,848 $0 Not Implemented
GT0680 # 02 Y:1999 02 1999 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $2,098 $3,500 Not Implemented
GT0680 # 03 Y:1999 03 1999 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,310 $450 Implemented
GT0680 # 04 Y:1999 04 1999 INSULATE BARE EQUIPMENT $1,120 $2,000 Not Implemented
GT0680 # 05 Y:1999 05 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,057 $4,527 Implemented
GT0680 # 06 Y:1999 06 1999 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $38,165 $11,480 Not Implemented
GT0673 # 01 Y:1999 01 1999 PAY BILLS ON TIME TO AVOID LATE FEES $6,000 $0 Not Implemented
GT0673 # 02 Y:1999 02 1999 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $5,110 $7,000 Not Implemented
GT0673 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,422 $7,508 Not Implemented
GT0673 # 04 Y:1999 04 1999 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $3,118 $5,050 Not Implemented
GT0673 # 05 Y:1999 05 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $410 $300 Not Implemented
GT0673 # 06 Y:1999 06 1999 COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES $29,340 $0 Not Implemented
GT0673 # 07 Y:1999 07 1999 RECYCLE CLEANING SOLVENT AND REUSE $107 $320 Not Implemented
GT0669 # 01 Y:1999 01 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,756 $60,795 Implemented
GT0669 # 02 Y:1999 02 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $641 $1,250 Implemented
GT0669 # 03 Y:1999 03 1999 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,935 $6,800 Implemented
GT0669 # 04 Y:1999 04 1999 USE DIRECT AIR SUPPLY TO EXHAUST HOODS $10,870 $7,700 Not Implemented
GT0669 # 05 Y:1999 05 1999 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $113,437 $0 Implemented
GT0669 # 06 Y:1999 06 1999 KEEP EQUIPMENT CLEAN $2,200 $1,000 Implemented
GT0669 # 07 Y:1999 07 1999 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $8,844 $32,000 Implemented
GT0669 # 08 Y:1999 08 1999 REUSE / RECYCLE/ SELL PAPER PRODUCTS $550 $200 Implemented
GT0669 # 09 Y:1999 09 1999 INSTALL AUTOMATIC PACKING EQUIPMENT $108,000 $100,000 Not Implemented
GT0664 # 01 Y:1999 01 1999 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $31,943 $0 Not Implemented
GT0664 # 02 Y:1999 02 1999 INSULATE BARE EQUIPMENT $13,210 $19,500 Implemented