IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

353

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0020 # 04 Y:1988 04 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,078 $500 Not Implemented
RU0017 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,392 $262 Implemented
RU0017 # 02 Y:1988 02 1988 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $4,029 $2,200 Implemented
RU0017 # 03 Y:1988 03 1988 IMPROVE LUBRICATION PRACTICES $614 $0 Not Implemented
RU0017 # 04 Y:1988 04 1988 COVER OPEN TANKS $875 $100 Implemented
RU0017 # 05 Y:1988 05 1988 INSTALL TIMERS AND/OR THERMOSTATS $5,472 $5,900 Not Implemented
RU0017 # 06 Y:1988 06 1988 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $2,496 $0 Implemented
RU0005 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,958 $184 Implemented
RU0005 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $791 $84 Implemented
RU0005 # 03 Y:1987 03 1987 INSULATE BARE EQUIPMENT $6,186 $292 Implemented
RU0005 # 04 Y:1987 04 1987 UPGRADE OBSOLETE EQUIPMENT $1,486 $0 Not Implemented
RU0005 # 05 Y:1987 05 1987 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $2,688 $0 Implemented
RU0001 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,628 $376 Implemented
RU0001 # 02 Y:1987 02 1987 COVER OPEN TANKS $3,290 $200 Not Implemented
RU0001 # 03 Y:1987 03 1987 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $822 $31 Implemented
RU0001 # 04 Y:1987 04 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,104 $0 Implemented
RU0001 # 05 Y:1987 05 1987 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,551 $0 Implemented
ST0040 # 15 Y:1985 15 1985 INSTALL TIMERS AND/OR THERMOSTATS $11,903 $675 Not Implemented
ST0040 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,017 $1,181 Implemented
ST0040 # 02 Y:1985 02 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,026 $64 Implemented
ST0040 # 03 Y:1985 03 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $730 $60 Implemented
ST0040 # 04 Y:1985 04 1985 USE COMPRESSOR AIR FILTERS $1,245 $0 Implemented
ST0040 # 05 Y:1985 05 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $9,896 $1,900 Implemented
ST0040 # 06 Y:1985 06 1985 RECOVER WASTE HEAT FROM EQUIPMENT $2,761 $1,900 Not Implemented
ST0040 # 07 Y:1985 07 1985 INSTALL / REPAIR INSULATION ON STEAM LINES $1,091 $1,422 Implemented