Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
384
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0051 # 04 Y:1986 | 04 | 1986 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,552 | $190 | Not Implemented |
CO0051 # 05 Y:1986 | 05 | 1986 | IMPROVE LUBRICATION PRACTICES | $1,043 | $0 | Not Implemented |
CO0051 # 06 Y:1986 | 06 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $578 | $200 | Not Implemented |
CO0051 # 07 Y:1986 | 07 | 1986 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $189 | $280 | Not Implemented |
CO0051 # 08 Y:1986 | 08 | 1986 | TURN OFF EQUIPMENT WHEN NOT IN USE | $80 | $100 | Not Implemented |
CO0051 # 09 Y:1986 | 09 | 1986 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $305 | $400 | Not Implemented |
CO0051 # 10 Y:1986 | 10 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,412 | $476 | Not Implemented |
CO0047 # 01 Y:1985 | 01 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,203 | $4,000 | Not Implemented |
CO0047 # 02 Y:1985 | 02 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $956 | $150 | Implemented |
CO0047 # 03 Y:1985 | 03 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $414 | $1,200 | Implemented |
CO0047 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $414 | $350 | Not Implemented |
CO0032 # 01 Y:1985 | 01 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $816 | $500 | Not Implemented |
CO0032 # 02 Y:1985 | 02 | 1985 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $816 | $2,000 | Implemented |
CO0032 # 03 Y:1985 | 03 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $4,062 | $596 | Not Implemented |
CO0032 # 04 Y:1985 | 04 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,406 | $0 | Not Implemented |
CO0032 # 05 Y:1985 | 05 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,972 | $3,600 | Implemented |
CO0032 # 06 Y:1985 | 06 | 1985 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $596 | $1,500 | Implemented |
CO0032 # 07 Y:1985 | 07 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $865 | $1,500 | Implemented |
CO0022 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,005 | $812 | Implemented |
CO0022 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $235 | $300 | Implemented |
CO0022 # 03 Y:1985 | 03 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,655 | $5,000 | Not Implemented |
CO0022 # 04 Y:1985 | 04 | 1985 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,408 | $2,500 | Not Implemented |
CO0022 # 05 Y:1985 | 05 | 1985 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $111 | $100 | Implemented |
CO0022 # 06 Y:1985 | 06 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,775 | $100 | Implemented |
CO0022 # 07 Y:1985 | 07 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,991 | $4,000 | Not Implemented |