Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

572

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0554 # 07 Y:1995 07 1995 USE SYNTHETIC LUBRICANT $19,628 $0 Not Implemented
GT0554 # 08 Y:1995 08 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,558 $3,000 Not Implemented
GT0554 # 09 Y:1995 09 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $6,693 $2,552 Implemented
GT0550 # 01 Y:1995 01 1995 RECOVER WASTE HEAT FROM EQUIPMENT $2,325 $4,100 n/a
GT0550 # 02 Y:1995 02 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $342 $230 n/a
GT0550 # 03 Y:1995 03 1995 REPAIR AND ELIMINATE STEAM LEAKS $70 $45 n/a
GT0550 # 04 Y:1995 04 1995 REPLACE BOILER $3,542 $7,100 n/a
GT0550 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,288 $6,243 n/a
GT0530 # 01 Y:1994 01 1994 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $27,400 $0 Not Implemented
GT0530 # 02 Y:1994 02 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $37,000 $13,000 Not Implemented
GT0530 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,760 $108,900 Not Implemented
GT0525 # 01 Y:1994 01 1994 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS $6,630 $5,000 Not Implemented
GT0525 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,470 $6,520 Implemented
GT0525 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,860 $1,150 Implemented
GT0525 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,170 $32,530 Implemented
GT0525 # 05 Y:1994 05 1994 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $7,600 $2,550 Not Implemented
GT0525 # 06 Y:1994 06 1994 COVER OPEN TANKS $2,280 $740 Not Implemented
GT0476 # 01 Y:1992 01 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,279 $9,740 Not Implemented
GT0476 # 02 Y:1992 02 1992 DISCONNECT BALLASTS $310 $320 Not Implemented
GT0476 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,790 $2,980 Not Implemented
GT0476 # 04 Y:1992 04 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $848 $24,790 Not Implemented
GT0476 # 05 Y:1992 05 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,776 $150 Not Implemented
GT0476 # 06 Y:1992 06 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,747 $450 Not Implemented
GT0476 # 07 Y:1992 07 1992 REPAIR AND ELIMINATE STEAM LEAKS $36,000 $3,380 Not Implemented
GT0476 # 08 Y:1992 08 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $980 $1,880 Not Implemented