Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
536
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0305 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $658 | $236 | Implemented |
OK0305 # 02 Y:1990 | 02 | 1990 | INSULATE BARE EQUIPMENT | $1,153 | $836 | Implemented |
OK0305 # 03 Y:1990 | 03 | 1990 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,336 | $3,123 | Not Implemented |
OK0305 # 04 Y:1990 | 04 | 1990 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $8,684 | $17,000 | Not Implemented |
OK0305 # 05 Y:1990 | 05 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,686 | $2,782 | Implemented |
OK0302 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $484 | $167 | Implemented |
OK0302 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $491 | $640 | Not Implemented |
OK0302 # 03 Y:1989 | 03 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $134 | $280 | Implemented |
OK0302 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $310 | $487 | Not Implemented |
OK0302 # 05 Y:1989 | 05 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $373 | $630 | Implemented |
OK0302 # 06 Y:1989 | 06 | 1989 | INSULATE BARE EQUIPMENT | $265 | $120 | Not Implemented |
OK0302 # 07 Y:1989 | 07 | 1989 | OPTIMIZE PLANT POWER FACTOR | $955 | $2,600 | Not Implemented |
OK0293 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $803 | $671 | Implemented |
OK0293 # 02 Y:1989 | 02 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $155 | $208 | Not Implemented |
OK0293 # 03 Y:1989 | 03 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,624 | $1,500 | Implemented |
OK0293 # 04 Y:1989 | 04 | 1989 | REPAIR OR REPLACE STEAM TRAPS | $6,091 | $7,500 | Implemented |
OK0293 # 05 Y:1989 | 05 | 1989 | USE OPTIMUM THICKNESS INSULATION | $959 | $1,320 | Not Implemented |
OK0293 # 06 Y:1989 | 06 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $104 | $222 | Implemented |
OK0281 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $200 | $89 | Implemented |
OK0281 # 02 Y:1989 | 02 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $123 | $240 | Implemented |
OK0281 # 03 Y:1989 | 03 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,427 | $1,500 | Implemented |
OK0281 # 04 Y:1989 | 04 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $26,441 | $5,000 | Implemented |
OK0281 # 05 Y:1989 | 05 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $190 | $448 | Implemented |
OK0281 # 06 Y:1989 | 06 | 1989 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,803 | $3,680 | Implemented |
OK0234 # 01 Y:1987 | 01 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,956 | $210 | Implemented |