Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
445
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0059 # 08 Y:1989 | 08 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $929 | $1,000 | Not Implemented |
WI0059 # 09 Y:1989 | 09 | 1989 | INSTALL SET-BACK TIMERS | $449 | $400 | Not Implemented |
WI0059 # 10 Y:1989 | 10 | 1989 | INSULATE BARE EQUIPMENT | $258 | $175 | Not Implemented |
WI0047 # 01 Y:1989 | 01 | 1989 | IMPROVE LUBRICATION PRACTICES | $3,210 | $500 | Implemented |
WI0047 # 02 Y:1989 | 02 | 1989 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $3,901 | $1,300 | Implemented |
WI0047 # 03 Y:1989 | 03 | 1989 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $238 | $0 | Implemented |
WI0047 # 04 Y:1989 | 04 | 1989 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $1,836 | $0 | Not Implemented |
WI0047 # 05 Y:1989 | 05 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,913 | $3,600 | Implemented |
WI0047 # 06 Y:1989 | 06 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,766 | $2,100 | Implemented |
WI0027 # 01 Y:1988 | 01 | 1988 | IMPROVE LUBRICATION PRACTICES | $5,446 | $0 | Not Implemented |
WI0027 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,450 | $0 | Implemented |
WI0027 # 03 Y:1988 | 03 | 1988 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $890 | $1,400 | Not Implemented |
WI0027 # 04 Y:1988 | 04 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,627 | $700 | Implemented |
WI0027 # 05 Y:1988 | 05 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $171 | $0 | Not Implemented |
WI0027 # 06 Y:1988 | 06 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $445 | $500 | Implemented |
WI0009 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $15,779 | $0 | Not Implemented |
WI0009 # 02 Y:1987 | 02 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $284 | $0 | Implemented |
WI0009 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,826 | $5,373 | Implemented |
WI0009 # 04 Y:1987 | 04 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,854 | $1,120 | Implemented |
WI0009 # 05 Y:1987 | 05 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,844 | $5,000 | Not Implemented |