Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
542
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1017 # 02 Y:2019 | 02 | 2019 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,627 | $231 | Not Implemented |
OK1017 # 04 Y:2019 | 04 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,214 | $3,590 | Not Implemented |
OK1017 # 01 Y:2019 | 01 | 2019 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,604 | $17,500 | Not Implemented |
OK0992 # 04 Y:2018 | 04 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $604 | $450 | Implemented |
OK0992 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $308 | $259 | Implemented |
OK0992 # 08 Y:2018 | 08 | 2018 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $360 | $45 | Not Implemented |
OK0992 # 07 Y:2018 | 07 | 2018 | INSTALL SET-BACK TIMERS | $2,280 | $1,284 | Implemented |
OK0992 # 05 Y:2018 | 05 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $208 | $0 | Implemented |
OK0992 # 01 Y:2018 | 01 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $525 | $1,755 | Not Implemented |
OK0992 # 02 Y:2018 | 02 | 2018 | INSTALL OCCUPANCY SENSORS | $171 | $1,243 | Not Implemented |
OK0992 # 06 Y:2018 | 06 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,701 | $15,796 | Implemented |
OK0992 # 09 Y:2018 | 09 | 2018 | PAY UTILITY BILLS ON TIME | $310 | $0 | Implemented |
OK0985 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,769 | $21,562 | Implemented |
OK0985 # 06 Y:2018 | 06 | 2018 | INSULATE BARE EQUIPMENT | $79,971 | $7,481 | Not Implemented |
OK0985 # 01 Y:2018 | 01 | 2018 | INSTALL SET-BACK TIMERS | $758 | $592 | Not Implemented |
OK0985 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,240 | $19,498 | Implemented |
OK0985 # 05 Y:2018 | 05 | 2018 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $12,555 | $3,157 | Not Implemented |
OK0985 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,033 | $7,422 | Implemented |
OK0976 # 01 Y:2017 | 01 | 2017 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $31,812 | $180,000 | Implemented |
OK0976 # 07 Y:2017 | 07 | 2017 | INSTALL SET-BACK TIMERS | $1,177 | $240 | Implemented |
OK0976 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,185 | $3,480 | Not Implemented |
OK0976 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,176 | $61,707 | Implemented |
OK0976 # 05 Y:2017 | 05 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,681 | $35,200 | Not Implemented |
OK0976 # 02 Y:2017 | 02 | 2017 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $8,586 | $3,840 | Implemented |
OK0976 # 06 Y:2017 | 06 | 2017 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $12,094 | $22,000 | Not Implemented |