IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

651

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0155 # 03 Y:1996 03 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $6,362 $1,600 Implemented
UF0155 # 04 Y:1996 04 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,264 $1,300 Implemented
UF0155 # 05 Y:1996 05 1996 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $10,500 $10,500 Implemented
UF0155 # 06 Y:1996 06 1996 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $902 $120 Implemented
UF0155 # 07 Y:1996 07 1996 CONTRACT A WOOD PALLET RECYCLING COMPANY $32,800 $0 Implemented
UF0134 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,418 $10,501 Not Implemented
UF0134 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,083 $5,832 Not Implemented
UF0134 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,277 $4,277 Not Implemented
UF0134 # 04 Y:1995 04 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $23,009 $38,849 Not Implemented
UF0134 # 05 Y:1995 05 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,519 $350 Not Implemented
UF0134 # 06 Y:1995 06 1995 INSTALL OCCUPANCY SENSORS $1,000 $1,200 Not Implemented
UF0134 # 07 Y:1995 07 1995 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $10,056 $18,750 Not Implemented
UF0134 # 08 Y:1995 08 1995 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $4,960 $3,650 Not Implemented
UF0135 # 01 Y:1995 01 1995 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,947 $1,500 Not Implemented
UF0135 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,929 $1,727 Not Implemented
UF0135 # 03 Y:1995 03 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $16,778 $17,592 Not Implemented
UF0135 # 04 Y:1995 04 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,379 $350 Not Implemented
UF0135 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,059 $846 Not Implemented
UF0135 # 06 Y:1995 06 1995 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $23,780 $15,700 Not Implemented
UF0135 # 07 Y:1995 07 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $31,315 $4,200 Not Implemented
UF0101 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,006 $327 Implemented
UF0101 # 02 Y:1994 02 1994 USE PHOTOCELL CONTROLS $1,094 $2,400 Not Implemented
UF0101 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,879 $5,038 Implemented
UF0101 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,260 $1,450 Implemented
UF0101 # 05 Y:1994 05 1994 INSTALL AN UNINTERUPTABLE POWER SUPPLY $30,000 $100,000 Not Implemented