IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

712

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0043 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $26,075 $60,530 Not Implemented
BD0043 # 04 Y:1995 04 1995 INSTALL OCCUPANCY SENSORS $1,283 $600 Not Implemented
BD0043 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,009 $7,635 Not Implemented
WI0227 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,083 $4,041 Implemented
WI0227 # 02 Y:1995 02 1995 REDUCE VENTILATION AIR $603 $1,000 Not Implemented
WI0227 # 03 Y:1995 03 1995 INSULATE BARE EQUIPMENT $1,090 $100 Not Implemented
WI0227 # 04 Y:1995 04 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $578 $0 Not Implemented
WI0227 # 05 Y:1995 05 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $293 $640 Not Implemented
WI0227 # 06 Y:1995 06 1995 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $16,579 $22,000 Not Implemented
WI0227 # 07 Y:1995 07 1995 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,300 $0 Not Implemented
WI0220 # 01 Y:1994 01 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,282 $20,000 Not Implemented
WI0220 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,005 $500 Not Implemented
WI0220 # 03 Y:1994 03 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $4,811 $3,581 Implemented
WI0220 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,994 $4,917 Implemented
WI0220 # 05 Y:1994 05 1994 INSTALL OCCUPANCY SENSORS $254 $300 Not Implemented
WI0220 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,037 $960 Not Implemented
WI0220 # 07 Y:1994 07 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,111 $2,550 Not Implemented
WI0220 # 08 Y:1994 08 1994 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $789 $0 Not Implemented
WI0220 # 09 Y:1994 09 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $575 $120 Implemented
WI0217 # 01 Y:1994 01 1994 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,885 $800 Not Implemented
WI0217 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,876 $2,250 Not Implemented
WI0217 # 03 Y:1994 03 1994 USE SYNTHETIC LUBRICANT $1,735 $0 Not Implemented
WI0217 # 04 Y:1994 04 1994 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $768 $1,400 Implemented
WI0217 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $624 $1,099 Not Implemented
WI0217 # 06 Y:1994 06 1994 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $1,381 $8,000 Not Implemented