Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,765

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0309 # 02 Y:2005 02 2005 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $3,338 $550 Implemented
WV0309 # 03 Y:2005 03 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,461 $760 Implemented
WV0309 # 04 Y:2005 04 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,239 $8,590 Implemented
WV0309 # 05 Y:2005 05 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,140 $98 Implemented
WV0309 # 06 Y:2005 06 2005 RECOVER WASTE HEAT FROM EQUIPMENT $1,646 $232 Implemented
WV0309 # 07 Y:2005 07 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,551 $19 Implemented
WV0309 # 08 Y:2005 08 2005 INSTALL OCCUPANCY SENSORS $1,334 $1,436 Not Implemented
WV0309 # 09 Y:2005 09 2005 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,138 $0 Implemented
WV0309 # 10 Y:2005 10 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,066 $507 Implemented
WV0309 # 11 Y:2005 11 2005 DEVELOP A REPAIR/REPLACE POLICY $1,012 $133 Implemented
WV0309 # 12 Y:2005 12 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $512 $480 Not Implemented
WV0309 # 13 Y:2005 13 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $374 $0 Not Implemented
WV0309 # 14 Y:2005 14 2005 RECOVER AND REUSE COOLING WATER $12,688 $5,135 Not Implemented
WV0306 # 01 Y:2004 01 2004 PREHEAT COMBUSTION AIR WITH WASTE HEAT $30,489 $20,910 Not Implemented
WV0306 # 02 Y:2004 02 2004 INSULATE BARE EQUIPMENT $17,374 $5,922 Implemented
WV0306 # 03 Y:2004 03 2004 RECOVER WASTE HEAT FROM EQUIPMENT $2,768 $660 Not Implemented
WV0306 # 04 Y:2004 04 2004 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $2,517 $370 Not Implemented
WV0306 # 05 Y:2004 05 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,967 $2,040 Implemented
WV0306 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,591 $420 Not Implemented
WV0306 # 07 Y:2004 07 2004 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,120 $520 Not Implemented
WV0306 # 08 Y:2004 08 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $985 $160 Implemented
WV0306 # 09 Y:2004 09 2004 DEVELOP A REPAIR/REPLACE POLICY $934 $160 Implemented
WV0306 # 10 Y:2004 10 2004 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $796 $40 Implemented
WV0306 # 11 Y:2004 11 2004 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $777 $1,060 Not Implemented
WV0306 # 12 Y:2004 12 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $696 $3,480 Implemented