Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,100
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0327 # 06 Y:1995 | 06 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,001 | $12,431 | Not Implemented |
MA0327 # 07 Y:1995 | 07 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,226 | $0 | Not Implemented |
MA0327 # 08 Y:1995 | 08 | 1995 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,903 | $1,500 | Implemented |
MA0327 # 09 Y:1995 | 09 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,213 | $0 | Implemented |
MA0327 # 10 Y:1995 | 10 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $277 | $500 | Not Implemented |
WI0227 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,083 | $4,041 | Implemented |
WI0227 # 02 Y:1995 | 02 | 1995 | REDUCE VENTILATION AIR | $603 | $1,000 | Not Implemented |
WI0227 # 03 Y:1995 | 03 | 1995 | INSULATE BARE EQUIPMENT | $1,090 | $100 | Not Implemented |
WI0227 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $578 | $0 | Not Implemented |
WI0227 # 05 Y:1995 | 05 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $293 | $640 | Not Implemented |
WI0227 # 06 Y:1995 | 06 | 1995 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $16,579 | $22,000 | Not Implemented |
WI0227 # 07 Y:1995 | 07 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,300 | $0 | Not Implemented |
WV0052 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $9,329 | $5,737 | Not Implemented |
WV0052 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $861 | $1,130 | Not Implemented |
WV0052 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,204 | $6,600 | Implemented |
WV0052 # 04 Y:1995 | 04 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $400 | $350 | Implemented |
WV0052 # 05 Y:1995 | 05 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,025 | $2,534 | Implemented |
WV0051 # 01 Y:1995 | 01 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $21,730 | $9,819 | Not Implemented |
WV0051 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,413 | $1,130 | Implemented |
WV0051 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,399 | $3,964 | Implemented |
WV0051 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,330 | $30,260 | Implemented |
WV0051 # 05 Y:1995 | 05 | 1995 | OPTIMIZE PLANT POWER FACTOR | $34,884 | $26,775 | Not Implemented |
WV0051 # 06 Y:1995 | 06 | 1995 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $41,711 | $1,550 | Not Implemented |
WV0051 # 07 Y:1995 | 07 | 1995 | INSULATE BARE EQUIPMENT | $890 | $1,508 | Not Implemented |
WV0051 # 08 Y:1995 | 08 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,247 | $15 | Not Implemented |