Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,100
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0171 # 07 Y:1993 | 07 | 1993 | INSTALL OCCUPANCY SENSORS | $737 | $1,800 | Not Implemented |
WI0171 # 08 Y:1993 | 08 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $522 | $375 | Implemented |
WI0171 # 09 Y:1993 | 09 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $346 | $0 | Implemented |
HO0037 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,969 | $155 | Implemented |
HO0037 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,247 | $141 | Implemented |
HO0037 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,496 | $5,188 | Not Implemented |
HO0037 # 04 Y:1993 | 04 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,177 | $800 | Not Implemented |
HO0037 # 05 Y:1993 | 05 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,303 | $2,218 | Implemented |
HO0037 # 06 Y:1993 | 06 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $19,005 | $1,050 | Not Implemented |
HO0037 # 07 Y:1993 | 07 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,188 | $1,200 | Implemented |
HO0037 # 08 Y:1993 | 08 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $180 | $0 | Not Implemented |
HO0037 # 09 Y:1993 | 09 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $26,898 | $1,000 | Implemented |
SD0042 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $718 | $925 | Implemented |
SD0042 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,484 | $1,484 | Not Implemented |
SD0042 # 03 Y:1993 | 03 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,759 | $20 | Implemented |
SD0042 # 04 Y:1993 | 04 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,264 | $10,000 | Not Implemented |
SD0042 # 05 Y:1993 | 05 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,580 | $0 | Not Implemented |
SD0042 # 06 Y:1993 | 06 | 1993 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $40 | $39 | Implemented |
SD0042 # 07 Y:1993 | 07 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $803 | $650 | Implemented |
SD0042 # 08 Y:1993 | 08 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,457 | $0 | Implemented |
SD0042 # 09 Y:1993 | 09 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $10,717 | $11,800 | Not Implemented |
SD0042 # 10 Y:1993 | 10 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,753 | $2,420 | Implemented |
UD0392 # 01 Y:1993 | 01 | 1993 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $26,912 | $34,000 | Not Implemented |
UD0392 # 02 Y:1993 | 02 | 1993 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $12,218 | $0 | Implemented |
UD0392 # 03 Y:1993 | 03 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $24,501 | $54,400 | Implemented |