Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,026
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0230 # 06 Y:1991 | 06 | 1991 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,264 | $0 | Not Implemented |
MA0230 # 07 Y:1991 | 07 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,201 | $430 | Implemented |
CO0228 # 01 Y:1991 | 01 | 1991 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,136 | $250 | Implemented |
CO0228 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $989 | $0 | Implemented |
CO0228 # 03 Y:1991 | 03 | 1991 | INSULATE BARE EQUIPMENT | $13,150 | $8,175 | Implemented |
CO0228 # 04 Y:1991 | 04 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $350 | $250 | Implemented |
CO0228 # 05 Y:1991 | 05 | 1991 | OPTIMIZE PLANT POWER FACTOR | $240 | $250 | Implemented |
CO0228 # 06 Y:1991 | 06 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $550 | $700 | Implemented |
CO0228 # 07 Y:1991 | 07 | 1991 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $8,524 | $16,400 | Implemented |
CO0228 # 08 Y:1991 | 08 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,217 | $2,755 | Implemented |
CO0228 # 09 Y:1991 | 09 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,540 | $7,500 | Implemented |
RU0131 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $10,853 | $0 | Not Implemented |
RU0131 # 02 Y:1991 | 02 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,417 | $46,695 | Not Implemented |
RU0131 # 03 Y:1991 | 03 | 1991 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $18,330 | $0 | Not Implemented |
ND0009 # 01 Y:1991 | 01 | 1991 | UPGRADE OBSOLETE EQUIPMENT | $943 | $858 | Implemented |
ND0009 # 02 Y:1991 | 02 | 1991 | OPTIMIZE PLANT POWER FACTOR | $4,932 | $2,835 | Implemented |
ND0009 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $971 | $0 | Implemented |
ND0009 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $420 | $0 | Implemented |
ND0009 # 05 Y:1991 | 05 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $470 | $200 | Implemented |
TN0440 # 02 Y:1991 | 02 | 1991 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $3,819 | $0 | Not Implemented |
TN0440 # 03 Y:1991 | 03 | 1991 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,084 | $7,500 | Not Implemented |
TN0440 # 04 Y:1991 | 04 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,173 | $1,480 | Not Implemented |
TN0440 # 05 Y:1991 | 05 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $2,953 | $1,380 | Not Implemented |
RU0128 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,552 | $0 | Implemented |
RU0128 # 02 Y:1991 | 02 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $554 | $42 | Implemented |