Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

16,829

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0340 # 05 Y:1988 05 1988 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,300 $1,800 Implemented
GT0340 # 06 Y:1988 06 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $213 $237 Implemented
RU0029 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $834 $322 Implemented
RU0029 # 02 Y:1988 02 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $654 $202 Implemented
RU0029 # 03 Y:1988 03 1988 INSTALL SET-BACK TIMERS $1,898 $0 Not Implemented
RU0029 # 04 Y:1988 04 1988 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,940 $0 Implemented
RU0029 # 05 Y:1988 05 1988 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $933 $0 Implemented
TN0350 # 01 Y:1988 01 1988 KEEP LAMPS AND REFLECTORS CLEAN $3,434 $3,103 Implemented
TN0350 # 02 Y:1988 02 1988 INSULATE BARE EQUIPMENT $1,360 $375 Not Implemented
TN0350 # 03 Y:1988 03 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $310 $0 Implemented
TN0350 # 04 Y:1988 04 1988 INSTALL SET-BACK TIMERS $221 $0 Implemented
TN0350 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $170 $108 Implemented
TN0350 # 06 Y:1988 06 1988 IMPROVE LUBRICATION PRACTICES $136 $60 Implemented
GT0341 # 01 Y:1988 01 1988 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $360 $550 Implemented
GT0341 # 02 Y:1988 02 1988 REDUCE VENTILATION AIR $2,230 $400 Implemented
GT0341 # 03 Y:1988 03 1988 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,170 $760 Not Implemented
GT0341 # 04 Y:1988 04 1988 KEEP LAMPS AND REFLECTORS CLEAN $1,730 $3,720 Not Implemented
GT0341 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $480 $460 Not Implemented
GT0341 # 06 Y:1988 06 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $111 $112 Not Implemented
GT0341 # 07 Y:1988 07 1988 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,850 $400 Implemented
UD0270 # 01 Y:1988 01 1988 REDESIGN PROCESS $3,796 $1,000 Implemented
UD0270 # 02 Y:1988 02 1988 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $1,575 $1,000 Implemented
KU0260 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,030 $500 Implemented
KU0260 # 02 Y:1988 02 1988 INSULATE BARE EQUIPMENT $1,114 $1,550 Implemented
KU0260 # 03 Y:1988 03 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $21,888 $2,000 Implemented