Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

17,026

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0261 # 07 Y:1988 07 1988 INSULATE BARE EQUIPMENT $2,592 $3,600 Not Implemented
KU0261 # 08 Y:1988 08 1988 IMPROVE LUBRICATION PRACTICES $1,192 $0 Not Implemented
GT0341 # 04 Y:1988 04 1988 KEEP LAMPS AND REFLECTORS CLEAN $1,730 $3,720 Not Implemented
GT0341 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $480 $460 Not Implemented
GT0341 # 06 Y:1988 06 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $111 $112 Not Implemented
GT0341 # 07 Y:1988 07 1988 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,850 $400 Implemented
GT0341 # 01 Y:1988 01 1988 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $360 $550 Implemented
GT0341 # 02 Y:1988 02 1988 REDUCE VENTILATION AIR $2,230 $400 Implemented
GT0341 # 03 Y:1988 03 1988 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,170 $760 Not Implemented
CO0125 # 01 Y:1988 01 1988 INSULATE BARE EQUIPMENT $4,009 $4,600 Not Implemented
CO0125 # 02 Y:1988 02 1988 INSULATE BARE EQUIPMENT $213 $50 Not Implemented
CO0125 # 03 Y:1988 03 1988 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $806 $250 Implemented
CO0125 # 04 Y:1988 04 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $415 $288 Implemented
MA0121 # 01 Y:1988 01 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,877 $0 Implemented
MA0121 # 02 Y:1988 02 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,535 $400 Implemented
MA0121 # 03 Y:1988 03 1988 DIRECT WARMEST AIR TO COMBUSTION INTAKE $992 $251 Not Implemented
MA0121 # 04 Y:1988 04 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,017 $200 Implemented
MA0121 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,134 $187 Implemented
MA0121 # 06 Y:1988 06 1988 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $7,432 $6,690 Implemented
MA0121 # 07 Y:1988 07 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $458 $0 Not Implemented
MA0121 # 08 Y:1988 08 1988 INSULATE BARE EQUIPMENT $17,117 $296 Not Implemented
MA0121 # 09 Y:1988 09 1988 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY $5,108 $4,000 Not Implemented
MA0121 # 10 Y:1988 10 1988 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $5,646 $3,015 Not Implemented
MA0121 # 11 Y:1988 11 1988 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $10,661 $15,422 Not Implemented
LT0117 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,190 $87 Not Implemented