IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,765

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0424 # 01 Y:1994 01 1994 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,026 $0 Implemented
UD0424 # 02 Y:1994 02 1994 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $539 $0 Not Implemented
UD0424 # 03 Y:1994 03 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,051 $2,500 Implemented
ND0174 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,033 $3,875 Implemented
ND0174 # 02 Y:1993 02 1993 OPTIMIZE PLANT POWER FACTOR $1,428 $4,920 Not Implemented
ND0174 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,131 $1,061 Implemented
ND0174 # 04 Y:1993 04 1993 OPTIMIZE PLANT POWER FACTOR $507 $810 Not Implemented
ND0174 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $162 $450 Not Implemented
WV0012 # 01 Y:1993 01 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,687 $1,500 Implemented
WV0012 # 02 Y:1993 02 1993 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,050 $1,800 Not Implemented
WV0012 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $302 $170 Implemented
WV0012 # 04 Y:1993 04 1993 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,915 $3,200 Not Implemented
WV0012 # 05 Y:1993 05 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $758 $570 Implemented
WV0012 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $53 $916 Implemented
UD0397 # 01 Y:1993 01 1993 COMBINE UTILITY METERS $838 $200 Implemented
UD0397 # 02 Y:1993 02 1993 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $4,462 $100 Implemented
UD0397 # 03 Y:1993 03 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $445 $20 Implemented
UD0383 # 01 Y:1992 01 1992 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,953 $500 Implemented
UD0383 # 02 Y:1992 02 1992 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $8,673 $2,000 Implemented
UD0383 # 03 Y:1992 03 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $11,174 $0 Not Implemented
UD0383 # 04 Y:1992 04 1992 RECOVER WASTE HEAT FROM EQUIPMENT $1,389 $400 Implemented
UD0383 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,329 $13,345 Implemented
UD0383 # 06 Y:1992 06 1992 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $15,637 $47,000 Not Implemented
UD0384 # 01 Y:1992 01 1992 OPTIMIZE PLANT POWER FACTOR $31,568 $41,000 Not Implemented
UD0384 # 02 Y:1992 02 1992 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $15,864 $22,000 Not Implemented