Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,302
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0020 # 02 Y:1985 | 02 | 1985 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $9,754 | $56,300 | Implemented |
MA0020 # 03 Y:1985 | 03 | 1985 | USE RADIANT HEATER FOR SPOT HEATING | $4,696 | $13,000 | Not Implemented |
MA0020 # 04 Y:1985 | 04 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $852 | $100 | Implemented |
TN0239 # 01 Y:1985 | 01 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,129 | $180 | Implemented |
TN0239 # 02 Y:1985 | 02 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,382 | $0 | Implemented |
TN0239 # 03 Y:1985 | 03 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,463 | $75 | Implemented |
TN0239 # 04 Y:1985 | 04 | 1985 | INSTALL SET-BACK TIMERS | $488 | $0 | Implemented |
UD0151 # 01 Y:1985 | 01 | 1985 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $162 | $0 | Not Implemented |
UD0151 # 02 Y:1985 | 02 | 1985 | INSULATE BARE EQUIPMENT | $1,349 | $315 | Implemented |
UD0151 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $795 | $284 | Not Implemented |
ST0019 # 06 Y:1985 | 06 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $666 | $150 | Implemented |
ST0019 # 07 Y:1985 | 07 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $74 | $55 | Not Implemented |
ST0019 # 08 Y:1985 | 08 | 1985 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,350 | $0 | Implemented |
ST0019 # 09 Y:1985 | 09 | 1985 | USE COMPRESSOR AIR FILTERS | $148 | $40 | Implemented |
ST0019 # 10 Y:1985 | 10 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $274 | $500 | Implemented |
ST0019 # 11 Y:1985 | 11 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $906 | $175 | Implemented |
ST0019 # 12 Y:1985 | 12 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,567 | $1,900 | Implemented |
ST0019 # 13 Y:1985 | 13 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,654 | $537 | Implemented |
ST0019 # 14 Y:1985 | 14 | 1985 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,858 | $150 | Implemented |
ST0019 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,367 | $1,116 | Implemented |
ST0019 # 02 Y:1985 | 02 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,428 | $56 | Implemented |
ST0019 # 03 Y:1985 | 03 | 1985 | INSTALL AUTOMATIC STACK DAMPER | $1,259 | $856 | Not Implemented |
ST0019 # 04 Y:1985 | 04 | 1985 | INSULATE BARE EQUIPMENT | $691 | $300 | Implemented |
ST0019 # 05 Y:1985 | 05 | 1985 | USE OPTIMUM THICKNESS INSULATION | $541 | $240 | Implemented |
OK0156 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $567 | $161 | Not Implemented |