Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
204
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0184 # 06 Y:1990 | 06 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $6,410 | $2,620 | Implemented |
MA0179 # 01 Y:1990 | 01 | 1990 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $13,039 | $43,000 | Not Implemented |
MA0179 # 02 Y:1990 | 02 | 1990 | RECOVER AND REUSE COOLING WATER | $10,670 | $8,250 | Implemented |
MA0179 # 03 Y:1990 | 03 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $11,908 | $2,350 | Not Implemented |
MA0179 # 04 Y:1990 | 04 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $554 | $70 | Implemented |
MA0177 # 01 Y:1990 | 01 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,107 | $14,700 | Not Implemented |
MA0177 # 02 Y:1990 | 02 | 1990 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $10,876 | $21,853 | Not Implemented |
MA0177 # 03 Y:1990 | 03 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $822 | $120 | Implemented |
MA0177 # 04 Y:1990 | 04 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,411 | $8,500 | Implemented |
MA0142 # 01 Y:1989 | 01 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $16,859 | $570 | Implemented |
MA0142 # 02 Y:1989 | 02 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $39,982 | $5,700 | Not Implemented |
MA0142 # 03 Y:1989 | 03 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $42,075 | $45,870 | Not Implemented |
MA0142 # 04 Y:1989 | 04 | 1989 | INSTALL SET-BACK TIMERS | $6,809 | $900 | Not Implemented |
MA0142 # 05 Y:1989 | 05 | 1989 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $43,200 | $381,000 | Not Implemented |
MA0142 # 06 Y:1989 | 06 | 1989 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $27,100 | $13,000 | Implemented |
MA0142 # 07 Y:1989 | 07 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $52,700 | $680 | Implemented |
MA0071 # 01 Y:1986 | 01 | 1986 | IMPROVE LUBRICATION PRACTICES | $4,493 | $3,458 | Not Implemented |
MA0071 # 02 Y:1986 | 02 | 1986 | INSULATE BARE EQUIPMENT | $13,827 | $2,280 | Implemented |
MA0071 # 03 Y:1986 | 03 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $126,986 | $6,650 | Implemented |
MA0071 # 04 Y:1986 | 04 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $27,051 | $2,280 | Implemented |
MA0071 # 05 Y:1986 | 05 | 1986 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,537 | $22,460 | Implemented |
MA0071 # 06 Y:1986 | 06 | 1986 | IMPROVE LUBRICATION PRACTICES | $5,049 | $490 | Not Implemented |
MA0071 # 07 Y:1986 | 07 | 1986 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $2,326 | $15,600 | Implemented |
MA0071 # 08 Y:1986 | 08 | 1986 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,104 | $6,688 | Implemented |
MA0072 # 01 Y:1986 | 01 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,220 | $200 | Implemented |