Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17,096
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0988 # 08 Y:2018 | 08 | 2018 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,857 | $11,500 | Not Implemented |
UD0988 # 09 Y:2018 | 09 | 2018 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,857 | $6,000 | Not Implemented |
IP0106 # 01 Y:2018 | 01 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,724 | $0 | Not Implemented |
IP0106 # 02 Y:2018 | 02 | 2018 | INSTALL OCCUPANCY SENSORS | $548 | $1,325 | Implemented |
IP0106 # 03 Y:2018 | 03 | 2018 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,543 | $9,687 | Not Implemented |
IP0106 # 04 Y:2018 | 04 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,159 | $21,897 | Implemented |
IP0105 # 01 Y:2018 | 01 | 2018 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,219 | $0 | Implemented |
IP0105 # 02 Y:2018 | 02 | 2018 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $670 | $0 | Not Implemented |
IP0105 # 03 Y:2018 | 03 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,081 | $702 | Implemented |
IP0105 # 04 Y:2018 | 04 | 2018 | INSTALL OCCUPANCY SENSORS | $863 | $474 | Implemented |
IP0105 # 05 Y:2018 | 05 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $36,239 | $98,464 | Implemented |
IP0105 # 06 Y:2018 | 06 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,424 | $7,315 | Implemented |
IP0104 # 01 Y:2018 | 01 | 2018 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,554 | $0 | Implemented |
IP0104 # 02 Y:2018 | 02 | 2018 | COMBINE UTILITY METERS | $2,606 | $0 | Not Implemented |
IP0104 # 03 Y:2018 | 03 | 2018 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,002 | $0 | Not Implemented |
IP0104 # 04 Y:2018 | 04 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $22,395 | $5,924 | Implemented |
IP0104 # 05 Y:2018 | 05 | 2018 | INSTALL OCCUPANCY SENSORS | $1,594 | $475 | Implemented |
IP0104 # 06 Y:2018 | 06 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,678 | $2,725 | Implemented |
IP0104 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,529 | $4,887 | Implemented |
OR0702 # 01 Y:2018 | 01 | 2018 | MAINTAIN CLEAN CONDITIONS BEFORE PAINTING | $20,800 | $7,140 | Not Implemented |
OR0702 # 02 Y:2018 | 02 | 2018 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $5,088 | $660 | Not Implemented |
OR0702 # 03 Y:2018 | 03 | 2018 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,409 | $1,005 | Not Implemented |
OR0702 # 04 Y:2018 | 04 | 2018 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $5,065 | $5,807 | Not Implemented |
IC0204 # 01 Y:2018 | 01 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $71,958 | $100,000 | Implemented |
IC0204 # 02 Y:2018 | 02 | 2018 | ADJUST PH FOR NEUTRALIZATION | $132,488 | $180,000 | Implemented |